What are the Phase “A” trips for Ctmnt Ventilation?
What trips on a Phase “B” signal for Ctmnt Ventilation?
What trips on a CVI signal for Ctmnt Ventilation?
What does the CIV Train A isolate/trip?
What does the CIV Train B isolate/trip?
What Ctmnt Ventilation trips on a Load Conservation?
What Ctmnt Ventilation doesn’t trip on a Load Conservation?
- CRDM fans (Nat Circ cooldown)
What fans start when a 1# in lower ctmnt signal is received?
How will VDC-207 (CONTAINMENT PRESSURE RELIEF VENTILATION UNIT INLET VOLUME DAMPER ) fail on a loss of ctrl air?
What starts/opens on a 1# in Ctmnt signal?
What ventilation system can be used to reduce pressure in ctmnt?
- CPS/CPX
What will give you a Containment Vent Isolation?
Which Cntmt Rad Monitors will give a Train “A” CVI?
Train A – 1101 and 1301/1305
Which Cntmt Rad Monitors will give a Train “B”CVI?
Train B – 1201 and 1401/1405
What Ctmnt Ventilation will trip on a charcoal filter fire?
What is your CEQ fan trying to maintain while its running?
< 4% Hydrogen atmosphere in Ctmnt
What are the places where the CEQ fans take a suction?
Which ONE of the following does NOT need to be realigned following a Phase A ctmnt isolation signal reset?
A. Control air to containment.
B. Containment upper ventilation fans.
C. RCP seal return.
D. Cooling water to reactor supports.
What provides power to CEQ fans?
EZC-B (Train B)
EZC-C (Train A)
Where does the CEQ fan exhaust to?
During normal plant operation, control air to Containment Pressure Relief Inlet Volume Damper, VDC-207, is lost due to a small leak at the air valve.
How is Containment Pressure Relief System operation affected? (ASSUME the leak does NOT result in a loss of control air to any other component or system).
A. The system is inoperable as the damper fails closed.
B. The system can be operated at full flow as the damper fails open.
C. The system can only be operated at the flow that existed at the time of the failure as the damper fails as is.
D. No effect, the damper has a full capacity bypass line.
Unit 2 is operating at 100% power. A small instrument air leak inside Containment causes a slow rise in Containment pressure. Containment pressure is currently 0.29 psig. In order to ensure that adequate margin to Containment Technical Specification pressure limits is maintained, which ONE of the following indicates the appropriate action to reduce Containment pressure?
A. Maximize NESW cooling to the Containment Ventilation Units
B. The Containment should be vented using the Containment Purge System.
C. The Containment should be vented using the Containment Pressure Relief system.
D. All Upper/Lower Containment Ventilation Fans (CUV/CLV) should be started or verified running.
Which Ctmnt Vent Fan has the only electric heater that is outside ctmnt?
If there is a fire in a containment ventilation related charcoal bed what happens w/ ZMO-10/20
ZMO-10/20 open but deluge and drains must be manually opened