At what NH should Condition Lever be moved to START/FEATHER?
Initial Fuel Flow?
10-19% NH,
(10% NH if ITT<50°, 15% NH if ITT >50°)
Fuel flow 40 ± 20Kg/hr
Verify increase in oil pressure between __% NH and __% NH?
Between 35% NH and 50% NH.
Confirm starter disengagement at __% NH by?
At 63% NH by -
* ENGINE START SELECT switch returns to null position.
* SELECT light . . . . . . . OFF
* GEN Load Meter indicates zero,
or positive for first engine start.
Normal idle NH?
75 ± 3%
Indications that Starter has failed to cut-out following an engine start?
START Light Remains Illuminated or a Negative Load on the Generator Load Meter.
(QRH procedure)
Aborted Engine Start memory items?
IMMINENT OVER TEMPERATURE, HUNG START or FAILURE TO LIGHT UP
(WITHIN 10 SECONDS)
Minimum MAIN BATT voltage for start?
(To maximise battery and starter/generator life)
22V
(Applies to Battery, GPU assisted, APU assisted and Cross Generator assisted starts. This applies to both the first and second engine.)
To maximise battery and starter/generator life, wait until MAIN BATT load is below ___ before starting second engine.
0.4
Engine Start - Tailwind Limits?
* GPU assisted start - __kt
* APU or Cross Generator assisted start - __kt
* Battery start - __kt
Cross generator start procedure?
After first engine start (GPU available):
1. DC CONTROL EXT PWR switch . . . . . . . . . . . . . OFF
2. MAIN BUS TIE . . . . . . . . . . . . . . . . . . . . . . . . . . . . TIE
Check GEN 2 is online.
Commence aircraft pushback and start second engine.
After second engine start:
3. MAIN BUS TIE . . . . . . . . . . . . . . . . . . . . . . . . . . . .OFF
Max starting ITT?
840°C to 900°C for 12 seconds.
900°C to 950°C for 5 seconds.
Starter Cranking Time Limits?
1st 1 minute on - 2 minutes off
2nd 1 minute on - 2 minutes off
3rd 1 minute on - 30 minutes off