What is the GOAL of the REACTOR TRIP EOP, 40EP-9EO02?
State ENTRY Conditions for RX TRIP EOP?
BOTH conditions exist:
What are the GENERAL guidelines for EXIT of a recovery procedure (EOP/ORP)?
2. EOP/ORP has accomplished its goals
What are the specific EXIT conditions for leaving the RX TRIP EOP?
OR
What TRM requires recording PZR Spray Valve cycles?
TRM 3.4.102.2
If LOGGING of Spray Valve requirements start when a Main Spray Valve is already open, do we need to log the CYCLE of that valve?
NO
If using an EOP during a Plant Cooldown or PZR Spray Valve Ops, what are done with the appendices that track the valve cycles and cooldown rates?
2. Test Log entry SHALL be made
When do the supply breakers to WRF open automatically? WHY?
When WRF loses power, what is impact to PVNGS?
Why is there a TIME LIMIT on aligning BDAS? And what is the Bases?
When assessing Reactivity Control for SFSC in RX TRIP EOP, what is done if All FSCEA’s don’t fully insert?
2. Adequate SDM, as required by TS
When assessing MVA during RX TRIP EOP, what are PK and PN requirements (minimum)?
2 trains of PK and 1 train of PN on SAME TRAIN
In an Uncomplicated RX Trip, what are the Acceptance Criteria for RCS Inventory Control?
What is the Acceptance Criteria for RCS Pressure Control in the RX TRIP EOP?
2. PZR Pressure trending to 2225-2275 PSIA
State Core Heat Removal criteria during RX TRIP EOP’s
U1 just had a RX TRIP, diagnosed as Uncomplicated. What is acceptance criteria for RCS Heat Removal per EOP?
During CTMT Isolation SFSC, “HI CTMT PRESSURE PRE-TRIP ALARM” comes in. What is done?
Operators should be alert that something MORE serious than uncomplicated RX Trip is occurring
Per RX TRIP EOP, what time is entered in Placekeeper for EOP Entry Time?
Time SPTA’s were entered
Per RX TRIP EOP, what is performed when RX Power is 2x10^-6% or Less?
Appendix 8, BDAS alarm check
Per RX TRIP EOP, what SFP parameters are monitored?
What are SHADED steps? Asterisks steps?
Continuous Use Trigger Steps (CRS can perform out of sequence - always applicable)
Per EOP’s, what is a Safety Function?
Condition or Action that prevents Core Damage or Minimizes RAD release to public
Define HARSH conditions in CTMT?
2. CTMT RAD Level > 10^8 mR/Hr
How do we verify MSIS?
2. MSIV, MFIV, BD IV’s are all Closed