How are all fire detectors tested?
Automatically when A/C PWR established
or
ENG/APU/CARGO test switch on FIRE/OVHT test panel
*wheel well not tested, must be done manually with WHL WELL switch on panel
Fire detectors are located at what positions?
APU Fire Warnings are provided at what locations?
FIRE/OVHT TEST SYS FAIL (center pedestal) switch/light illumes?
Dual loop failure has occured
*pressing switch will RESET SYS to exclude failed system
Indications of ENG FIRE?
How are ENG FIRE HANDLES unlocked?
Electrically when fire signal detected
Manually via override switch below handle
Fire Protection available for ENG + APU (how many bottles)?
ENG = 2 bottles
APU = Single bottle
Fire Protection available for CARGO COMPARTMENTS?
3 AGENT BOTTLES
Fire Protection available for WHEEL WELL?
None
*QRH will advise crew to lower gear
All A/C FIRE WARNINGS can be cancelled via _____ except for?
Pressing Master WARN/CAUT switch
Ground APU FIRE (wheel well)
What happens when ENG FIRE HANDLE is pulled?
What happens when APU Fire Switch pulled?
L/R ENG OVHT Panel light?
Ruptured pneumatic duct in ENG Nacelle
How long is fire suppression supplied for in FWD/AFT CARGO COMPARTMENTS on ER A/C?
195 mins
via:
*meets 180 min ETOPS req
FWD/AFT CARGO COMPARTMENTS have how many smoke detectors?
TWO
Pressing ARMED on FWD CARGO FIRE switch?
<em>BELLS-BOTTLES-FANS-FLOWS</em>
Pressing ARMED on AFT CARGO FIRE switch?
Same as FWD but PACKS HI-FLOW is inhibited