(High Rise Defined)
Any structure ______ or higher.
75’
There are two basic styles of High-rise construction:
2. Old Style
New Style Construction:
Old Style Construction:
(New Lightweight High-Rise)
This will probably become the _________ style of high-rise buildings.
third
(Roofs)
Minimum ____ hour fire rating.
2
(Floors)
Floors will usually be a ____ hour fire rating.
2
Most windows in ___________ construction cannot be opened.
“New Style”
(Potential fire area)
2. 70 percent
Remember; fire resistance is intended to provide resistance to collapse of structural members and floors and resistance to the passage of fire through floors and horizontal barriers. Fire resistance itself is not concerned with ____________ or control and movement of toxic combustion products
life safety
(Fire Load Includes)
Commercial high-rise structures contain approximately ___________ per square foot.
30 to 35 lbs.
(Plenum Space)
This space can occupy up to _______ of the overall floor space in a high-rise.
25%
Important safety rule***
___________________________________
PROTECT YOURSELF FIRST AND THEN PROTECT OTHERS
(Engine Company Functions)
-100’
(Check the valve)
_____________ will ascend a stairway without checking the condition of the __________________.
- standpipe valve
(Line Deployment)
The __________ determines where the standpipe will be connected. (Floor of the fire or floor below)
officer
(Line Deployment)
(1/2) If the fire is __________ upon arrival you will hook the first line to the ___________. NOTE: This line will be the protection line for the fire floor door.
- floor below
(Line Deployment)
(2/2) If nothing is showing from the street, then the officer makes the choice based on the following:
A. Confirm the fire floor
B. Officer checks the door to the fire floor, if hot then hook up below
C. If the door is cool, officer secures door opening and examines the interior area
D. If _____________ or _______ is indicated, the line may be hooked up at the __________ floor for a quick attack.
When you open the door to the fire floor and you find blackened out conditions, you must orient yourself before entering. This can be done by dropping down one floor and quickly observing the floor layout.
CAUTION: __________________________
NOT ALL FLOOR PLANS ARE INDENTICAL
(Fire Attack)
The nozzle person must check the air from the nozzle and be alert to fire conditions. ___________________________!!!
Look up, look up, look up!!!
(Fire Attack)
________ open the nozzle on the light smoke and heat.
Do not
Once the fire is found, open the line at the ceiling for several seconds to reduce some heat and scatter the water over the fuel. This must be a _____________ or extremely ____________ as to not violate the atmosphere.
- tight fog
(Truck company functions at high-rise fires)
All truck companies assigned to a high-rise incident must focus on the _________________. Because of the limited amount of truck companies and the amount of work expected of them, crew members must not engage a hose line unless it is needed to protect an occupant or another fire fighter from heat and fire
proper functions
(Truck company functions at high-rise fires)
The primary function of the truck companies will be:
_________________________________
Some secondary functions will be salvage, overhaul
Rescue, support to the attack team, and provide ventilation