What is mechanical system of a building?
Mechanical systems most commonly relate to heating ventilation and air conditioning systems, but they can also relate to transportation systems such as lifts and escalators, elements of infrastructure, industrial plant and machinery, and so on.
How buildings losses heat?
What are the main heat sources in a building?
What are the main heat generators?
How is heat distributed within a building?
Heat generators can be local to the demand for heat, or can be centralised and distributed, either within a single building or on a wider basis as part of a district heating network. Heat distribution can be by:
How heat can be delivered within a building?
What are the heat transfer mechanisms?
How heating can be controlled?
What is Combined heat and power (CHP) plant?
Combined heat and power (CHP), sometimes referred to as cogeneration, is a process in which the heat that is created as a by-product of power generation is captured and used rather than simply being wasted.
What is Air Handling unit?
Air handling units (AHU, sometimes referred to as ‘air handlers’) form part of the heating, ventilating and air conditioning system (HVAC) that supplies, circulates and extracts air from buildings. Generally, they are connected to the ductwork that supplies air to and extracts air from the interior and can provide ventilation, heating, cooling, humidity control and filtration.
What is Fan Coil units?
Fan coil units (FCU) consist of only a fan and a heating or cooling element, are located within the space they are serving, and are generally not connected to ductwork. They may either just recirculate internal air, in which case a separate ventilation system is required, or may introduce s proportion of ‘fresh’ air that is mixed with the recirculated air.
What is Energy Centre?
Energy Centre is general term of the main heat generating plant and associated equipment. A modern energy centre typically contains a combined heat and power unit, back up boiler, thermal storage vessel, water treatment equipment and expansion vessels.
Heat is then distributed to the network through flow and return pipework.
What is Heat Interface Units (HIU)?
Heat Interface Units (HIU) are typically used during the construction of large apartment complexes and social housing projects. Here rather than each property or dwelling being fitted with an individual boiler, a central boiler is used to provide heat and domestic hot water to all dwellings.
What are the factors determining the choice of ventilation systems?
What are the main methods of ventilations?
How supply and extract ventilation system work?
A supply and extract system comprises a central handling unit (AHU) typically containing separate supply and extract funs, air filter and heating coil. A ductwork system is used to supply and extract air from around the building. the heating coil can provide the main source of heat for the building.
What are the main method of managing ventilation in a building?
What HVAC stands for?
Heating, ventilation and air-conditioning system
What are the types of air condition systems?
What is VAV?
What are the chilled beams?
What are chilled ceilings?
What are split systems?
Split systems are made up of two components: one or more indoor room cooling units and an outdoor refrigerator unit which dumps heat taken from the building.
the indoor and outdoor units are linked by pipes which transport refrigerant between the units.
How can you control building services?