N1 limits
Min - 51% red
Cautionary (auto only) - 51-60% yellow
Continuous - 60-100.1% green
take-off (5 min) - 100.1-103.2% yellow
Max t/o (5 min) - 103.2% yellow/red
Transient (30 sec) - 103.8% red
note: transient can’t be used intentionally; N1 can go below 60% when gen and other systems are on
N2 limits
Min - 95%
cautionary - 95-101% yellow
continuous - 101-103% green
Max - 103% red
transient (10 sec) - 108%
Caut: when 103 is shown it is anywhere between 102.5 and 103.49 so you could be in the transient regime without realizing
Note: can’t intentionally use transient
ITT limits - normal ops
Max continuous - 755 C green
T/O (5 min) - 755-810C yellow
T/O max (5 min) - 810 C
Transient (5 sec) - 860C red
can’t intentionally use transient
ITT limits (start)
Max - 870 C green
Transient - 1090 (linear variation above 870 10 sec and 980 2 sec)
can’t intentionally use transient
Torque limits
Max Cont - 100% green
T/O (5 min) - 100-108.5 yellow
Max T/O (5 min) - 108.5
Transient (6 sec) - 115%
can’t intentionally use transient
Nr power on limits
Min - 95% red
Caut - 95-101 yellow
Continuous - 101-103% green
Max - 103%
Trans (10 sec) - 108%
can’t use transient intentionally
Nr power off limits
Transient (10 sec) - 80%
Min - 90%
Cont - 90-110%
Max - 110%
power off is defined as a split by at least 1% in N2/Nr
Fuel px limits
Caut - 0-7 psi yellow
Cont - 7-25 psi
max 25 psi
Min fuel
planned fuel reserve shall be no less than 142 lb in #1 cell
but shall land with no less than 50 lb in #1 cell
warn: sideward flight / xwind hover when indicated fuel is <22 may cause flameout
note: don’t have to combo planned fuel reserve and min fuel
Eng Oil Px limits
min - 40 psi
caut (with N1<72%) - 40-80 psi
Cont - 80-110 psi
max - 110 psi
note during cold starts oil px can temporarily exceed 110 psi
Eng Oil Temp
Min oat for start - -25C
Cont - 10-115 C
max 115C
transient (5 min with n1 61+-1) - 127C
XMSN oil px
min - 30 psi
Cont - 30-55 psi
Caut - 55-70 psi yellow
Max - 70 psi red
XMSN oil temp
Min oat for start - -25
Cont - 0-115C
Max - 115C
Eng start limits batt
40 sec on 60 sec off
40 sec on 60 sec off
40 sec on 30 min off
Eng start limit with ext pwr
25 sec on 30 sec off
25 sec on 30 sec off
25 sec on 30 min off
Gen limits
Cont - 0-200A
Max - 200A
trans (5 sec) - 300A
Aux Gen limits
Cont - 0-150 A
Max - 150 A
Trans (5 sec) - 150 A
Hyd limits
Min - 1200 psi
Caut - 1200-1400 psi
Cont - 1400-1600 psi
Max - 1600 psi
Vne
in accordance with chart but nominally 152
Vne ifr
lesser of 145 kias or the chart
V mini (ifr)
60 Kias
V min app
60 kias
Vmax app
130 kias
Min auto speed without close ext reference
60 kias