What are the two independent oxygen systems in the aircraft?
One for the
flight deck and one for the cabin
What is the purpose of portable oxygen bottles?
To allow the flight
attendants to move about the cabin during an emergency and unpressurized or as first aid
Where is the flight crew’s supplemental oxygen stored?
In the wardrobe
behind an access panel. In a high pressure storage bottle 50 cubic feet.
What is the pressure of a full oxygen storage bottle?
1850
What happens if the bottle pressure drops below 1,410 psi?
an OXY LO
PRESS caution message will be displayed
What is the function of the blowout disk?
it will pop out in the event that
the oxygen bottle over pressurizes due to large changes in ambient
temperature.
Where is the blow out disk located
left fuselage by pax door
What color is the bblow ouut disc
Green
What does it mean if the blowout disk is missing?
It means that all of the
oxygen in the crew bottle has been dumped overboard
A panel located on the
right forward fuselage just aft of the radar.
What components are included in the service panel for the crew oxygen
bottle?
A filler valve and an electrical pressure gauge
10.How is supplemental oxygen delivered to the flight crew?
Through 3 quick
donning oxygen masks. have a mic in it and inflatable harness
What features do the flight crew oxygen masks have?
full face masks with
an inflatable harness and an internal microphone
12.What do the flow blinkers indicate?
Display a yellow cross anytime
oxygen is flowing through the mask or when the harness is inflated. Press to test button
13.How can the oxygen mask be removed from its container?
by grasping the red
release levers that protrude through the container doors
14.What happens when the release levers are grasped?
Opens the harness
inflation valve, which causes the harness to expand
15.What does the PRESS TO TEST AND RESET lever do?
allows flow to the
mask to be tested without removing the mask from the container
16.What does the N/100% lever control?
Controls the mixture of oxygen and
ambient air that is supplied to the user
17.What happens when the N/100% lever is in the N position?
provides the
appropriate mixture of pressurized oxygen and ambient air for the cabin
altitude
18.What happens when the N/100% lever is in the 100% position?
provides
pure oxygen on demand
19.What is the function of the emergency flow control knob?
To supply 100%
continuous oxygen under positive pressure to the mask wearer and to
purge the mask
20.How is oxygen supplied to passengers?
Via chemical oxygen generators
Cabin oxygen installed where
cabin overhead
21.What triggers the chemical oxygen generators?
When one of the masks
in a passenger service unit is pulled down, a pin in the oxygen generator