Who has to test your system?
-Alberta Boilers Branch
Piping System
Grid
-one compressor with feeder lines branching off a main line that starts out with a larger diameter pipe and then gets slower as it goes down the line
Decentralized
Loop system
-recommends - two or more compressors feed a single system
How to avoid moisture problems in your system
-sloping the line coming from the compressor away for the compressor with the drop on top
FRL
-filter, regulator and lubricator
Code dictates your system have?
-gauge, drain, safety relief valve
How does sealing happen in directional control valves in pneumatics?
Packed bore
-have o-rings fixed in grooves in the bore of the valves
Packed spool
-have o-rings fit into grooves machined into the spool
Sliding plate (rotary disc)