Which engine is installed?
IAE V2500-A5
What is the thrust output of the engine?
27.000 lbs
What are the components of the LP stage?
What are the components of the HP stage?
- 2 stage HP turbine
Which rotor is connected to the accessory gearbox?
N2
Which aircraft components are driven by the AGB?
How is the FADEC powered?
By aircraft power for 5 min on startup, then shutdown. Dedicated alternator >10% N2
What are the three idle modes?
When is approach idle selected?
In flight when flaps are extended
How many igniters are used for automatic start?
One
When will the ignition turn on/off in the automatic start sequence?
On - After dry crank sequence
Off - 43% N2
What is the effect on thrust of FADEC reverting to degraded N1 mode?
N1 is defined as a function of TLA only, overboots can occur.
How many igniters are used for a manual start?
2
When is ignition automatically selected on?
At what engine speed will the start valve close?
43% N2
What faults will the auto start system abort for?
What is the max EGT during starting?
635°C
How are the thrust reversers actuated?
Hydraulically
What is the maximum continuous oil temperature?
155°C
What is the minimum oil temperature for start?
-40°C
What is the max starter duty cycle?
Will the manual start sequence be aborted by the FADEC for start faults?
No
When do the pack valves close during the automatic start sequence?
When ENG MODE is selected to IGN/START
When does the start valve open during the automatic start sequence?
When ENG MASTER switch is selected to ON