Holiday testing of thick-film linings shall be carried out with a ,,,,,,, in accordance with NACE ,,,,,,,
high-voltage detector
RP0188.
Holiday testing of thin-film linings should be performed with a ,,,,,
low-voltage (67.5 volts) wet sponge detector
A tank bottom lining with a measured thickness of 15 mils should be tested by……
low-voltage (67.5 volts) wet sponge detector
All lining inspectors should be ,,,,,,,,,,,????? of coating and lining practices
either NACE or SSPC certified, or should have demonstrated a thorough knowledge