——— is not a fuel gas?
Natural gas
MAPP gas
Oxygen gas
Acetylene gas
Oxygen Gas
Which gas has the highest flame temperature?
Acetylene gas,
Propane gas
MAPP gas
Natural gas
Acetylene gas
What is the first step in putting out a fire in the hoses of an oxyacetylene outfit?
- Use a fire extinguisher on the hoses
- close only the acetylene cylinder valve
- close only the oxygen cylinder valves
- close both the oxygen and acetylene cylinder valves
Close both the oxygen and acetylene cylinder valves
You should never lubricate regulators or parts of the torch
- true
- false
True
One of the quickest ways to tell if an acetylene hose has a leak in it
Smell in the air, acetylene has a strong, pungent odour
The critical point of free acetylene is ____ psi (____kPa) at 21 degrees Celsius; if the temperature increases, the pressure becomes critical at a _____ pressure
28 psi
193 kPa
Lower
The acetylene fittings are made of _____________, to prevent a fire or possible explosion from happening.
A. Copper or red brass.
B. Steel iron or yellow brass.
C. Red brass or steel
D. Iron red, brass or yellow brass.
B. Steel, iron, or yellow brass (yellow brass preferred)
The fuel gas not shipped in liquid form for welding is?
A. Oxygen.
B. MAPP
C. Propane.
D. Natural gas.
D. Natural Gas
Why is acetylene gas dissolved in liquid acetone and shipped in cylinders filled with a porous filler?
Acetone keeps acetylene from reaching its critical point.
Acetone dissolves acetylene, and allows more acetylene to be stored at a higher pressure
According to the OHS regulation, compressed oxygen gas can be only be used to:
A. Operate a pneumatic
B. Accelerate combustion of fuel gases.
C. Start an internal combustion engine.
D. Ventilate a workplace.
B. Accelerate combustion of a fuel gases
The occupational health and safety regulation require that the device required for closing the valve on acetylene cylinder must be:
A. Immediately available, close to the cylinder itself.
B. Immediately available, at the nearest tool crib.
C. Within 50 m of the cylinder.
D. Within 100 m of the cylinder.
A. Immediately available, close to the cylinder itself.
Containers used for shipping compressed gases are called?
Cylinders
Cylinders are withdrawn from service at the slightest indication of
Damage
The pressure in a full oxygen cylinder at 21°C is
2200 psi
15 mPa
The safety device in oxygen cylinder valve is _______ activated?
Pressure
What are three things you should do if a cylinder valve is damaged?
A. Tag cylinder to indicate fault.
B. Move to a ventilated/ open area
C. Notify supplier for pick up.
Acetylene cylinders must be upright to prevent _______ plugging the equipment
Acetone
Free acetylene is dangerous when stored at pressures above?
15 psi
103 kPa
The safety devices on an acetylene cylinder are ______ activated?
Heat - fusible links at top and bottom of cylinder
Oxygen cylinders are opened __________
Acetylene cylinders are opened ________
Oxygen cylinders are opened all the way
Acetylene cylinders are opened a 1/4 to 1/2 turn
Manifold systems are used to increase ___________ of acetylene.
Draw limit for a large job
Liquid fuel cylinders are designed to allow the liquid to ___________ when the cylinder valve is opened and gas escapes
Evaporate, boil
When cylinders are too low on gas to be used, they should be marked _______?
M.T.
Cylinder valves should always be __________ open momentarily before the regulator is attached and ______ when your work is finished.
“Cracked” open
Closed