A. F.A.I. on the inlet side, upstream of the ejector pot.
B. At 6 foot intervals.
3. A hot water line needs a hot water return when the furthest fixture exceeds: A. 15 feet. B. 20 feet. C. 50 feet. D. 100 feet.
B. 20 feet (new code).
C. 50 feet (old code)/
4. Galvanized steel pipe can be used on the outside leader line for a maximum of: A. 5 feet. B. 10 feet. C. 15 feet. D. 20 feet.
C. 15 feet.
D. Cast iron drainage pipe may be used.
6. Extra strong galvanize wrought iron is schedule: A. 40 B. 80 C. 160 D. 30.
B. 80.
7. The color code for recirculation water pipe for an in-ground pool is: (old code) A. Green. B. Gray. C. Yellow. D. Light blue.
D. Light blue.
8. The color code for a potable water pipe for make up water to a swimming pool is: A. Green. B. Gray. C. Yellow. D. Light blue.
A. Green.
9. The color code for backwash and wash water pipe is: A. Green. B. Gray. C. Yellow. D. Light blue.
B. Gray.
10. The color code for well water pipe is: A. Yellow. B. Gray. C. Green. D. Red.
D. Red.
11. The color code for chlorine pipe is: A. Yellow. B. Gray. C. Green. D. Red.
A. Yellow.
12. Any structure. basin, chamber or tank containing an artificial body of water for swimming, diving or recreational bathing shall be considered a swimming pool if it has a minimum depth of: A. 1-ft. B. 2-ft. C. 3-ft. D. 4-ft.
B. 2-ft.
B. Residential 5 stores or less.
14. Which vent arrangement indicates continuous venting: Figure 29) A. D. B. A and D. C. C and D. D. B and D.
C. C and D.
15. Which vent arrangement indicates a revent: Figure 29) A. A. B. C. C. D. D. B.
A. A.
16. Which vent arrangement indicates a back vent: Figure 29) A. A. B. C. C. D. D. B.
D. B.
17. Which vent arrangement indicates a common vent: (Figure 29) A. C and D. B. A and B. C. B and D. D. A and B.
A. C and D.
18. Which type of venting is considered the best type of venting: A. Circuit venting. B. Loop venting. C. Crown venting. D. Continuous venting.
D. Continuous venting.
19. What type of venting best describes a vent connection at the junction of two fixture drains and serving as a vent for both fixture traps and drains: A. Revent. B. Back vent. C. Common vent. D. Circuit vent.
C. Common vent.
20. What type of venting best describes a vertical vent that is continuation of the drain to which is connects: A. Loop vent. B. Circuit vent. C. Continuous vent. D. Loop vent.
C. Continuous vent.
D. A pipe connecting upward from a soil or waste stack to a vent stack for the purpose of preventing pressure changes in the stack.
22. What fixture unit value for a Jacuzzi bath tub: A. 1 B. 2 C. 3 D. 4.
B. 2.
23. How many water closets private (1.6 gpf) would be permitted on a 3 inch horizontal soil branch pipe: A. 1 B. 2 C. 3 D. 6.
D. 6.
24. How many water closets flushometer tank, public or private would be permitted on a3 inch horizontal soil branch pipe: A. 1. B. 2. C. 5. D. 6.
C. 5.