D. Preparing lead pipe for a solder nipple.
2. Hydrostatic test should be done by using: A. Water. B. Smoke. C. Air. D. Kerosene.
A. Water.
3. The center to-center measurement of 1 on figure 9 is most nearly equal to: A. 20 inches. B. 25 inches. C. 30 inches. D. 65 inches.
B. 25 inches.
4. The center to-center measurement of 2 on figure 9 is most nearly equal to: A. 20 inches. B. 25 inches. C. 30 inches. D. 45 inches.
B. 25 inches.
5. The center to-center measurement of 3 on figure 9 is most nearly equal to: A. 30-1/2 inches. B. 28-7/8 inches. C. 28-3/4 inches. D. 27-3/4 inches.
C. 28-3/4 inches.
T=1.414x20=28-1/4”.
6. The center to-center measurement of 4 on figure 9 is most nearly equal to: A. 23-1/2 inches. B. 28-1/4 inches. C. 29 inches. D. 31-1/4 inches.
B. 28-1/4 inches.
7. An offset is made in a hot water riser that eventually fills with air. As a result, which one of the following is most likely to occur: A. Water hammer. B. Decrease flow. C. Increase flow. D. Noise during flow.
B. Decrease flow.
8. If a set of sanitary plans are drawn to scale of 1-1/2inches equal to one foot, the plans are said to be: A. One sixteenth size. B. One eighth size. C. One quarter size. D. One tenth size.
B. One eighth size.
1-1/2=3/2x1/12=1/8
9. When the first of the falling water has acquired a velocity greater than that of the water following it, the development that may be expected is: A. Back pressure. B. Siphonage. C. Water-hammer. D. Surging.
B. Siphonage.
The pump generally selected to discharge the contents of a sewage ejector pot is: A. Reciprocating pump. B. Centrifugal pump. C. Rotary pump. D. Ejector pump.
B. Centrifugal pump.
11. Six water closets are connected in a battery without individual vents. A pipe that is connected to the soil stack and the branch soil pipe between the 5th and sixth water closets is defined as: A. Loop vent. B. Relief vent. C. Circuit. D. Yoke vent.//
C. Circuit.
12. A type of fitting best suited as a foot-piece (connecting a stack to a building drain) is: A. Two 45* ells and a 10 inch nipple. B. A long sweep 90* ell with a test tee. C. Wye and 1/8 bend. D. Two 45 ells and a 6-inch nipple.
C. Wye and 1/8 bend.
13. A six inch fresh-air-inlet plate has forty-eight 3/4-inch diameter holes drilled into the plate. The number of 1/2-inch diameter holes needed to meet the minimum requirements is most nearly: A. 50. B. 45. C. 40. D. 35.
C. 40.
6x6=36, .75x.75=0.5625 .5625x48=27 36-27=9 ,5x,5=0.25 9/0.25=36 holes.
D. Oakum, lead, hammer and outside irons.
15. Building (house) traps when below a cellar floor shall be made accessibly by extension of two hand holes. The maximum length hand holes may extend above the center line of the drain is; A. 2 ft. B. 4 ft. C. 3 ft. D. 1-1/2ft.
D. 1-1/2ft.
B. Provide a gravity drip connection to the soil or waste pipe.
17. A privy vault is equivalent to a: A. Water closet. B. Building house sewer. C. Private house sewer. D. Building house drain.
A. Water closet.
C. Decrease the overall scouring action in this drain.
19. Proper venting eliminates most causes of the loss of trap seals. One method of the trap seal loss that venting has no bearing on is: A. Momentum. B. Evaporation. C. Back pressure. D. Self-siphonage.
B. Evaporation.
20. Soil and waste stack are being installed in a 25-story building.Yoke relief vents should be provided: A. 12th and 20th floors. B. 5th and 15th floors. C. 8th and 19th floors. D. 10th and 20th floors.
B. 5th and 15th floors.
21. A branch vent that serves two or more traps and extends from in front of the lat fixture connection of a horizontal branch to the vent stack is: A . Loop vent. B. Circuit vent. C. Relief vent. D. Continuous vent.
B. Circuit vent.
22. A centrifugal pump operates at best advantage when set: A. 32 ft. above water line. B. 20ft. above water inlet. C. 10 ft. above water inlet. D. 10 ft. below water line.
D. 10 ft. below water line.
23. If a set of sanitary planes are drawn to scale of 3/4 inch = 1 foot, the plans can be said to be: A. 1/16 size. B. 1/8 size. C. 3/8 size. D. 3/16 size.
A. 1/16 size.
24. Even if entire vent system were perfectly installed, a fixture trap can till lose its seal. The normal reason for such occurrence is most likely: A. Evaporation. B. Back-pressure. C. Siphonage. D. Capillary action.
D. Capillary action.