Handeling EMER Steps
Before start flow
External/Battery Switch…………………As required
DC MAster Switch…………………………On
Doors……………………………………………..Closed-Lights Out
Beacon…………………………………………..On
7 ITEMS
Power Levers…………………………………Idle
Prop Levers……………………………………Feather
Fuel Levers…………………………………….Off
Generators……………………………………..Off
Bleed Air Switch…………………………….Off
Boost Pumps………………………………….On
Outside………………………………….Check, Prop Area Clear
After Start Flow
Power Levers………………………………Advance to Idle NG +15%
Generators…………………………………..On, Lights out
Valve Heaters………………………………On
Position Lights……………………………..On
Cabin signs………………………………….As requ.
Taxi Lights……………………………………On
Pitot Heater Switch……………………..On
Flaps…………………………………………….Down to 10*
Autofeather SW……………………………Select
Radio Master…………………………………On
Generator Load……………………………Less then 0.5
Power Levers……………………………….Idle
Prop Levers………………………………….Full Fine
Shutdown flow
Parking Brake………………………………on
Prop Levers………………………………….Feather
Avionics Master……………………………Off
Generators…………………………………..Off
Fuel Levers………………………………….Off
Then
Electric Equipment……………………..Off
Taxi Light…………………………………….Off
Bleed Air SW………………………………Off
Boost Pumps………………………….(-5%)Off
DC Master and Batt SWS………….Off
Stabdby Horizon……………………….Off
Control Locks if AC is unnattended