What is the purpose of the Sump System?
What is the system designator for the Service Building Sump System?
WB
What is the system designator for the Turbine Building Sump System?
WP
What is the system designator for the Conventional Waste Water System?
WC
What is the system designator for the Roof Drain System?
WD
What is the system designator for the Yard Drain System?
WY
What is the system designator for the Ground Water Drainage System?
WZ
What is the system designator for the Diesel Generator Room Sump System?
WN
What are the switch positions for the Service Building Sump Pumps, and what is the normal position?
2. The switches are normally in AUTO
How will the Service Building Sump Pumps operate with their control switches in MANUAL?
The pumps will run until shutdown
How will the Service Building Sump Pumps operate with their control switches in AUTO?
2. Hi-Hi level in the sump the other pump will start, and both will continue to run until the low level is reached
What are the inputs into the Service Building Sumps?
Where does the Service Building Sump System discharge to?
The Service Building Sump System discharges to the Initial Holdup Pond
What is the purpose of the Service Building Sump System?
2. Send the waste water to the Conventional Waste Water Treatment System(WC)
What is the purpose of the Turbine Building Sump System?
What are the inputs to the Turbine Building Sump System?
What is the precaution associated with opening a drain valve in one of the Circulating Water(RC) Sump Pits?
There must be a dedicated individual at the RC Pump Suction Isolation Valve Pit to perform a flood watch
What are the inputs to the Turbine Building Sump System(WP)?
2. Auxiliary Building Floor Drain Sump C(Unit 2)
Where does the Turbine Building Sump System discharge to?
The Conventional Waste Water Treatment System(WC) Initial Holdup Pond
How many Turbine Building Sump System Pumps are there?
There are three Turbine Building Sump System Pumps
What affect will placing the Turbine Building Sump Pumps in AUTO have on their operation?
With the control switch in AUTO:
What affect will placing the Turbine Building Sump Pumps in ON have on their operation?
With the control switch in ON the pump will run until it is stopped
What affect will 14 feet of water in the Turbine Building Sump have on the TB Sump Pumps?
If level reaches 14 feet(emergency Hi level) any remaining pumps with control switches in OFF will start
What is the affect on the Turbine Building Sump System if EMF-31 produces a Trip 2 signal?