Under river rail operations
Tube walls are how thick?
2.2.1
2 and 2 1/2 feet
Most tubes were bored into solid bedrock, but a few tubes run through composites of clay, sand, and silt.
Under river rail operations.
Personnel and evacuating passengers should walk in which area when in the tunnel?
2.2.1
Outside the rails, opposite the 3rd rail.
Under river tubes.
T/F
Most tubes have no access to the adjacent tube throughout the underwater areas.
2.2.2
True
Under river tubes.
Under the river tubes are ——- than underground tunnels.
2.2.2
Narrower
Under river tubes.
In MOST cases, it is the location of the last emergency exit and the last crossover to the adjacent tube until ?
2.4
The other side of the river
Under river tubes
They have the standard Subway emergency exit. How are the opened?
2.5.1.
Subway emergency tool, the triangle key
Billy bar (not essential)
Under river tubes
Some exit stairways are narrow and steep, while others are wider, with a pitch that is comfortable to walk on. Stairways are constructed of either concrete or metal. The metal stairs are often —— with —— treads.
2.5.2
Metal Steeper
Open treads
Under river tubes
Lighting is present but may need to be enhanced. —— will provide illumination without adding extra heat.
2.5.3
Glow sticks
Under river tubes
Crossovers, also known as passageways, are connections between adjacent tunnels.
They are located only in ——— areas and at the end of under river 2.6.1
Underground areas
Under river tubes
What is the most common configuration of a crossover in these tubes? 2.6.1.
Track level
Under the river rail Operations.
All under the river standpipes in the NYCT system are ?
2.7.1
Wet
City Main fed
Under river rail operations.
T/F
Standpipes are city main fed and there are pumps to augment the pressure.
2.7.1
False
No Pumps to augment pressure
Under river rail operations.
Siamese connections are usually located?
2.7.1
At the emergency exit closest to the river.
Under river rail Operations
Standpipes have a 2 1/2 inch outlet and are located every ——- feet throughout the under river tubes.
Section valves are located approximately —— feet.
2.7.1
Every 200 feet (outlets)
Approximately 600 feet
(Section valves)
Under river rail operations.
Sound powered phone jacks are located at?
2.7.1
Standpipe outlets (200 feet)
Under river rail operations.
Section valves are located every 600 feet throughout the under river tubes. They are often found at? 2.7.1.
Base of emergency exits
Under river rail operations
——— pound Dry Chem extinguishers are located at power removal boxes, approximately every ——- feet.
2.7.2
20 pound
600 feet (same as section valves)
Under river rail Operations
EED are
located where?
2.7.2
Both ends of each under river tube at the base of the emergency exits
Also at the first blue light south of the station on the southbound track.
Under river rail operations.
What numbers can be used to provide an approximate location of the incident?
2.7.3
Standpipe numbers are sequential
Under river rail operations.
T/F
If enough personnel are on scene and conditions warrant the HT relay should be established.
2.9.1
True
Under river rail operations.
For max repeater coverage, the IC should ensure that a member operating on the ——- channel is at —— level in a position at the closest station on both side sides of the river. 2.9.2.
Repeater channel
Street level
Under river rail operations
T/F
At present, there are no repeater antennas at most emergency exits, and no repeater coverage inside most emergency exit stairways.
2.9.2
True
Under river rail operations.
Sound powered phone systems have been installed in every under river tube, except the ——- between Brooklyn and Manhattan.
2.9.3
Joralemon Tubes
Under river rail Operations
In the under river tubes, phones are designated by blue lights are found near the emergency power removal boxes, approximately —— feet apart. 2.9.4.
600 feet