MDE vital alarms
Crankcase pressure high
JW temp high
Overspend trip activated
Lube oil pressure pressure shutdown
Lube oil pressure shut down.
Lube oil temp high
SSDG Vital alarms
Just temp high
Overspend trip activated
Lube oil pressure pressure shut down
Lube oil pressure shut down
Reduction gear vital alarms
Thrust bearing temp high
Lube oil temp high
Lube oil pressure low
MPCMS vital alarms
Primary computer fail
Secondary computer fail
Program control fail
Power available
MDE permissives
MDE pre lube
RED GEAR pre lube
Turning gear disengaged
Baring gear disengaged
Fuel switch on.
RED GEAR De clutched
Air shut downs open
Situations for RMD
Special sea detail
Mooring
Anchoring
ATON
towing
Ice breaking in restricted waters
Ice escorts
Whenever the CO deems necessary
MDE IDLE RPM
350
MDE full ahead RPM
900
MDE Overspeed alarm
918
MDE overspeed shutdown
1017
MDE Normal L/O PSI
26-80
MDE normal temp
140° to 205°
MDE L/O temp high alarm
214
MDE L/O filter differential
0-15 PSI
MDE L/O Differential alarm
16psi
MDE F/O PSI
38-100
MDE F/O PSI low alarm
<37 PSI
MDE F/O high PSI
> 102 PSI
MDE F/O primary filter DIFF.
<15PSI
MDE F/O secondary filter DIFF.
<10 PSI
MDE J/W PSI
15 to 40 PSI
Immediate standby
a) ECC remains manned by EOW and JE.
b) Pre-lube pump on
c) Fuel valves open
d) Sea water valves open
e) Air supply valves open
f) Alarm panel energized
g) Pre-heaters energized
h) Engine(s) shall be run as required to maintain lube oil temperature above 140° F
i) Local control panels in “REMOTE”
30 minute standby
a) EOW may stand down from ECC but shall remain up and about
b) JE will remain in ECC with the exception of engineering rounds.
c) MDE local control panel in “local,” Pre-lube pump off
d) Fuel valves open
e) Sea water valves open
f) Air supply valves open
g) Alarm panel energized
h) Pre-heaters energized
i) All other local control panels in “remote”
j) Engine(s) shall be run as required to maintain lube oil temperature above 120°F
Two hour standby
(a) Pre-lube pump offituara
oib) Fuel valves open
nismo
beatabion
(WOWO
c) Sea water valves open
d) Air supply valves open
e) Alarm panel energized
f) Pre-heaters energized
g) All local control panels in “Local”