A building design for residential apartments has been established with a separation distance of 1.2 m from a building face to a property line. Which one of the following is required for the design of that wall?*
A) Availability of natural light based on adjacent buildings
B) Encroachment of building projections into the setback
C) Fire rating requirements for exit stairs
D) Percentage of unprotected openings permitted in the wall
D) Percentage of unprotected openings permitted in the wall
Identify the information required at the design development phase.
Submit the design development documents to the Client, advise the Client of any adjustments to the Construction Cost Estimate and obtain the Client’s approval prior to proceeding to the Construction Documents Phase.
Client/municipality
Architect/for all
Mech
Structure
Electrical
Landscape
List of consultants to take on
Determine the engineering services required at the design development phase for structure
Determine the engineering services required at the design development phase for Mech
Determine the engineering services required at the design development phase for elec
Determine the engineering services required at the design development phase from the municipality
Determine the engineering services required at the design development phase from Landscape
Identify the documentation required to obtain the client’s approval of the design development. dwg(5) report (8)
and including:
Prepare an updated design development report incorporating, as appropriate:
Describe the impact of the analysis of the building code and of universal accessibility at the design development phase.
Describe the impact of sustainable design at the design development phase.
What is the main structural problem that should be considered by the engineer during DD?
Alternate framing plans + systems, including their associated costs.
What information does the architect need to provide to the structural engineer? (7)
1 - Geoech report
2 - Restrictive Areas for Supports
3 - Areas / uses / finishes
4 - Code (prelim w FRs)
5 - Location + Size of Openings
6 - Construction Materials
7 - Project Delivery
What level of detail is required for the specifications during DD?
Outline Spec (table of contents from all consultants - review with client)
With whom should the architect share the ‘signed off’ schematic design.
All consultants & staff
What should the architect and structural engineer consider together during DD? (3)
1 - Availability of Material
2 - Appearance
3 - Functional Considerations (project location, cost, schedule, time of the year)
List 5 uses of client review documents
1 - Client Review + Approval
2 - AHJ + Public Group Review
3 - Consultant Input / Coord.
4 - Update Cost Estimate
5 - Basis of CDs
What should the electrical engineer and the design team resolve together during DD? (7)
1 - Anticipated ELEC. LOAD + allowance for future
2 - rqrmts for INCOMING SERVICES + space rqrmnts (vault / sub-station)
3 - DISTRIBUTION of power / utilization of voltage
4 - locations for elec / comm / data CLOSETS
5 - rqrmts for EMBEDDING CONDUIT
6 - light FIXTURE selection + ceiling rqmts
7 - SWITCHing + CONTROLs
8 - Telecom / data / fire alarm / security / pa SYSTEMS
List the 8 KEY architectural tasks to be executed during DD.
1 - prep / COORD ASMECL designs
2 - outline SPEC
3 - perform prelim. ENERGY MODEL analysis
4 - AHJ reviews
5 - prep PRESENTATION material
6 - update construction COST estimate
7 - update SCHEDULEs
8 - CODE review
What should the mech engineer and the design team resolve together during DD? (7)
1 - NATURAL ventilation
2 - central vs. indirect HEAT / COOLING
3 - SIZE of hvac equip
4 - energy analysis + MODELLING
5 - size + location of major DUCTs PIPEs
6 - plumbing FIXTURES + CONTROLS
7 - other FEATURES (noise control)
*future operating costs associated
What information does the architect need to provide to the electrical engineer? (3)
1 - Typ. Areas (function, size, finish, materials, lighting)
2 - Rqrmnts for future expansion/flexibility
3 - Project Delivery
What are the 3 components of Client Design Review documents.
1 - Drawings
2 - Outline Spec
3 - Design Report