When will the FADEC abort a Start:
What are the indications that the start cycle is complete?
Start cycle will end at approximately 55% N2 and Ignition A or B will go out.
What is the max tailwind for engine start?
10 knots
What STATUS page do you want up.
Which Electrical Bus supports the engine start.
Central Bus.
With a normal ground start which Battery starts the jet.
2 Battery.
After Start, do you push the GPU button out before you give the signal to disconnect or vice/versa.
Yes, push GPU button out before you give the signal.
What’s a good indication your going to have a HOT START.
If you see your ITT go past 12 o’clock, shut it down!
You go to start 2nd engine without, why does the N2 increase to to 72% on the number one engine prior to starting number 2 engine.
If your doing a Battery start (no GPU) how long should wait to start the 2nd engine and why.
2 minutes, because it’s such a heavy draw on the system.
1.Why do we want to abort the start if there’s no light off within 10 seconds.
2. What could possibly be the cause of it.
Because of all the fuel your dumping in and you could have a bad igniter.
What does FADEC NOT protect.
SWITCH:
What takes place when you turn your Start Knob to RUN.
How many seconds would indicate a Hung Start and what does a Hung Start mean.
= 60 seconds.
= You have normal light off BUT the engine isn’t spinning fast enough to reach its RPM.
Could be a bad Starter.
During Start you don’t have N1 rotation. What could be the problem.
N1 probe could be iced up. Usually happens in cold weather.
When do you not dry motor an engine after a abnormal start.