The provisions of this section (Appendix Chapter 4) shall apply to _ hour care facilities in a Group R- occupancy licensed by a governmental agency.
24
This refers to the specific fire code requirements for certain care facilities.
Special Requirements, Occupancy: R-3 Non-Ambulatory Patient - 6 or less Clients, Two stories max or not more than 3,000 sq feet contact Fire Authority within ______ hours of admission.
48
This is the time frame for notifying the Fire Authority regarding bedridden clients.
Clients who become bedridden as a result of a temporary illness: A temporary illness is an illness which persists for ______ days or less.
14
This defines the duration for which a client can be considered temporarily ill.
A bedridden client may be retained in excess of the ______ days upon approval by the Department of Social Services.
30
This allows for flexibility in housing bedridden clients beyond the standard duration.
Group R-4 occupancies, where non-ambulatory clients are housed above the first story and there is more than 3,000 square feet of floor area above the first story shall be constructed of not less than ______ hour fire-resistance-rated construction throughout.
1
This specifies the fire-resistance requirements for certain Group R-4 occupancies.
Special Requirements, Occupancy: Group R-3.1 - Hallway Doors leading to Bedrooms shall be ______ automatically closing or by smoke detector activation.
1 3/8”
This measurement pertains to the specifications for hallway doors in Group R-3.1 occupancies.
Special Requirements, Occupancy: School Facilities for Kindergarten Through 12 Grade: Exit Discharge shall be ______ foot wide.
20
This defines the minimum width for exit discharges in school facilities.
Minimum clear width, Corridor: Group R-2.1 occupancies shall have ______ inches on floors housing non-ambulatory clients and ____ inches on floors housing ambulatory clients.
60 & 44-44
This is the required corridor width for non-ambulatory clients in Group R-2.1 occupancies.
Group R-4 occupancies shall have ______ inches on floors housing clients.
44
This specifies the corridor width for Group R-4 occupancies.
Group R-2.1 and Group R-4 occupancies housing more than ______ non-ambulatory clients above the first floor shall be provided with two vertical exit enclosures.
6
This indicates the threshold for requiring additional exit enclosures.
Residential Care for the Elderly facility serving Alzheimer clients may be fenced and gates therein equipped with locks, provided safe dispersal areas are located not less than ______ feet from the buildings. dispersal areas shall be size to provide an area not less than__square feet per occupant. 
50 & 3
This ensures safety measures for facilities serving Alzheimer clients.
Dispersal areas shall be sized to provide an area of not less than ______ square feet per occupant.
3
This specifies the minimum space requirement for dispersal areas.
Special Requirements, Occupancy: Day Care Facilities - Under age 7 or containing more than 12 children per story shall not be located above the ______ floor.
4th
This regulation is aimed at ensuring safety for young children in day care facilities.
Special Requirements, Occupancy: Large Family Day-Care Home: Not less than ______ days prior to date decision will be made on application, the zoning administrator shall mail ___ radius of exterior boundaries of proposed family care home.
10 & 100’
This outlines the notification period for zoning administrators regarding family care homes.
“Property owners within [X] feet of the exterior boundaries of a proposed family care home shall be notified.”
100
This specifies the distance for notification related to family care home applications.
Group E occupancies shall front directly on a public street or an exit discharge not less than _______ feet wide.
20
The exit discharge to the public street must be unobstructed and maintained only as access to the public street.
According to Appendix Chapter 4, RCFE equals?
Residential Care Facilities for Elderly
Also referred to as Residential Care For Elder.
RF and RCRE are regulated pursuant to?
Both A & B are applicable.
R-4: Safety Padding shall comply with?
R3.1 - Ambulatory with 50 or more: Corridors and Aisles shall be a minimum of _______ inches?
44
## Footnote
This is the minimum width requirement for corridors and aisles.
The State Fire Marshal shall adopt separate building standards specifically relating to fire and life safety in Family Daycare Homes, which is Title _______ of the California Code of Regulations.
24
This title outlines specific standards for Family Daycare Homes.
Special Requirements, Occupancy: Large Family Day-Care Home: One _______ extinguisher is required.
2A10BC
This is the type of extinguisher mandated for large family day-care homes.
Fire Department Access Roads shall support _______ Thousand Pounds.
75
This weight capacity is necessary for safe access.
Fire Department Access Roads shall comply with?
Compliance with these codes is essential for safety.