Pulling an engine fire switch:
(3 electric, 2 fluid, 1 air)
Arms both extinguishers,
Trips associated engine generator, removes power to thrust reverser isolation valve
Closes associated engine and spar fuel valves, depressurizes/shuts off fluid to associated engine-driven hydraulic pump
Closes associated engine anti-ice valve
APU fire switch
Arms extinguisher
Trips generator field and breaker
Closes APU fuel valve
Closes air inlet door
Shuts down APU (if auto shutdown does not occur)