API Specific Gravity Test
American Petroleum Institute Specific Gravity Test
F-76 Sampling Requirements
What is the sediment limit for the Filter Separator discharge?
2.64 mg/L
What are the CCFD limits?
40ppm
2.64 mg/L
Where are the storage tank samples taken from?
Stripping tanks
Where do we take samples when transferring from storage to service tanks?
Transfer pump discharge.
What are the F/O sediment limits?
DoD 0.1%
Non-DoD 0.05%
What are the JP-5 sampling requirements?
What is a FSII test?
Fuel Service Ice Inhibitor
DIEGME
What is the designed flow rate during refueling?
3000 GPM
6000 GPM- with two risers.
GTG burn rate?
250 GPH
Why do we conduct the API specific gravity test?
For stability and to ensure we are receiving the correct fuel.
How far do we fill F/O service and storage tanks?
95% underway
80% inport
What are the JP-5 sampling limits?
5ppm
2.0 mg/L
F-76 sampling requirements?
What types of fuel does BENFOLD carry?
DFM (F-76) and JP-5 (F-44)
What is the minimum flashpoint for DFM and JP-5?
140* F
What is the max BS&W for F/O?
0. 05% for Non-DoD
What is the max tank percentage we are allowed to fuel underway and inport?
95% underway
80% inport
How many fuel storage tank groups do we have and how many storage tanks do we have?
6 tanks groups.
21 storage tanks.
What is the max F/O fill rate at sea and inport?
1000 GPM underway.
400 GPM inport
What is the designed flow rate of the deck connection?
3000 GPM
6000 GPM with two risers
IAW NSMT 541
What is the criteria for a service tank sample?
Clear and Bright
What is clear and bright?
Clear: Absence of sediment
Bright: free of water