What are the auto shutdown criteria?
GTG Specs?
LP Air Usage?
Who signs MLOCS?
AUX1 Frame #?
126
MER1 Frame #?
174
AUX2 Frame #?
220
MER2 Frame #?
254
Shaft Alley Frame #?
300
3 Gen Frame #?
338
MGTEC Conditions?
Where are the Full Power Run procedures?
MUFP
What are the parameters of the APD?
Auto Parallel Device
30* of Phase Angle (15* each direction).
0.2Hz
0.5V
What is the most important space to save?
MERII
Both shafts.
2 GTG, and fuel tanks for 3 GTG.
2 LPACs.
What is important to remember about starting 3 GTG?
To open vent casing on SWS pump, to release built up air.
What is the over speed alarm for GG?
9700 RPM
What is the max speed of the GG?
10,122 RPM, requires overhaul.
What is the over speed alarm for PT?
3852 RPM
What is the over speed trip for PT?
3960 RPM
What is max PT speed?
5,585, requires overhaul.
What is high vibes alarm and trip for GG?
6mils, 7mils
What is high vibes alarm and trip for PT?
7mils, 10mils
What is high TIT?
1600* alarm, 1625* trip.
What is low L/O alarm and trip on GTM?
15 PSI, 6 PSI