ACGEN_001
(All) Identify location and function of the position, anti-collision and landing light switches:
POS/STROBE Lights Switch – Glareshield, Right Side
• OFF - Extinguishes fwd & aft pos. strobe lts.
• POS - Illuminates forward and aft position lights only.
• BOTH - Illuminates the forward and aft position lights,
and strobe lights are activated when airborne.
ANTI-COLLISION Lights Switch – Glareshield, Right Side
• OFF - Extinguishes anti-collision lights.
• ON - Illuminates upper and lower anti-collision lights.
WING LDG LTS Switch (L/R) – Glareshield, Left Side
• RET - Retracts wing landing lights.
• EXT OFF - Extends wing landing lights with lamps off.
• EXT ON - Extends wing landing lights with lamps on.
ACGEN_003
(All) Explain the function of the 3 positions of the EMER LTS Switch (Flight Deck):
OFF
ARM
ON – Simulates elec power failure. All emer evacuation lights & EMER LIGHT NOT ARMED message illuminate.
ACGEN_004
(All) Can emergency lights can be activated from the Flight Attendant’s Panel regardless of flight deck switch position?
• Switch to ARM (mometary) then releasing to ON illuminates emergency evacuation lights regardless of position of flight deck EMER LTS switch.
ACGEN_005
(All) Specify the number and location of all emergency exits.
10 aircraft emergency exits: • Two flight deck sliding windows. • Forward cabin door. • Forward galley door. • Aft galley door. • Aft cabin door (through tailcone). • Four overwing exits.
ACGEN_006
Purpose of emergency lighting? How long the battery packs will provide power?
Emer. lighting system provides minimal illumination of flight deck, cabin & exit areas to facilitate aircraft evacuation
• W/ flight deck EMER LTS switch in ARM position, emergency lights automatically illuminate when power from DC Emergency Bus is lost.
• System uses incandescent bulbs powered by rechargeable batt packs which provide power for 15’
ACGEN_007
Locate the flight deck indications for access, emergency and cargo doors:
OAP will display amber caution msg and illuminate DOOR cue if any of following doors is not closed and/or latched:
• Access: ACCESS COMPT, ELECT COMPT, AFT STAIRWAY
• Emergency: FWD CABIN, FWD GALLEY, AFT GALLEY, AFT CABIN, AFT STAIRWAY.
• Cargo: FORWARD CARGO, MID CARGO, AFT CARGO
ACGEN_008
Describe the standby lighting that is available on Emergency Power:
When EMER PWR (emergency power) switch is selected ON w/ normal electrical power off and BATT switch ON, standby lighting will illuminate CA’s and First FO’s instrument panel floodlights.
• Lights receive pwr from emergency DC bus and DC transfer bus.
• Floodlights can be individually adjusted from min - max intensity using respective floodlights knob.
• Immediate bright floodlighting can be obtained by moving the THDRSTRM LT switch to ON.
ACGEN_010
Recommended pavement width for a 180 turn:
Recommended pavement width for a 180° turn is 125 feet.
ACGEN_011
Describe relationship of the nose, wing and tail during a turn:
Nose clearance guarantees tail or wing tip will clear, however, if wing tip alone clears, the tail may not clear.
ACGEN_012
Describe how nose gear landing and taxi lights are affected when the landing gear handle is moved to the up position:
ACGEN_013
Understand how the strobe lights are affected when the aircraft becomes airborne:
Wing tip strobes operate only when POS/STROBE switch is in BOTH and nose wheel is off the ground
ACGEN_015
Function of AUTO position of NO SMOK and SEAT BELTS switches:
NO SMOK Switch
• AUTO - Chime sounds when landing gear is extended.
SEAT BELTS Switch
• AUTO - FASTEN SEAT BELTS and RETURN TO CABIN signs illuminate when slats are extended. Chime sounds.
ACGEN_017
OAP / Master Caution alerts for an open DOOR indication:
ACGEN_019
Understand the function of the MD-90 Status Cue Light on the Enhanced Overhead Annunciator Panel (EOAP):
• Status Cue Light (blue) below EOAP screens. Replaces MONITOR light. Advises second level message is stored in status buffer requiring no procedural action by flight crew.
ACGEN_024
Understand the operation of the Master Caution lights:
MASTER CAUTION Light (2) (amber)
• Both lights will illuminate when caution messages are displayed on the OAP.
• Pushing either light will extinguish both MASTER CAUTION lights and reset the system for subsequent indications.
ACGEN_018
Describe the operation of the Master Warning lights:
MASTER WARNING Light (2) (red)
• Both lights will illuminate when red lights on annunciator panel illuminate.
• Pushing either light will extinguish both MASTER WARNING lights and reset the system for subsequent indications.
ACGEN_020
Recall flight crew oxygen system location and indications.
ACGEN_021
Describe the function of the PASS OXY MASK Switch:
CAUTION: Holding switch in EJECT position in excess of five seconds may cause damage to the oxygen compartment latches
ACGEN_022
Recall the OAP Blue Advisory Lights associated with an activated passenger oxygen system:
CABIN OXYGEN ON - Left and right aft cabin oxygen door latches have been activated.
ACGEN_023
Recall minimum crew oxygen pressure:
• Minimum Pressure 1,000 psi