AIR SPACE REQUIREMENTS
SCHOOL ROOMS
3.00 cubic meters
WORKSHOPS, FACTORIES, OFFICES
12.00 cubic meters
HABITABLE ROOMS
14.00 cubic meters
MINIMUM EASMENTS
URBAN AREAS
3m
AGRICULTURAL AREAS
20m
FOREST AREAS
40m
MINIMUM ROOM SIZES
ROOM FOR HUMAN HABITATION
6.00 sqm
2.00m
KITCHEN
3.00 sqm
1.50m
TOILET & BATH
1.20 sqm
0.90m
Eaves over required windows
shall at least
be 750mm
Minimum Requirements: Group A Dwellings
Foundation
At least ___ thick and at least ____ below the surface of the groun
250mm thick
600mm below
Floor
First floor live load:
200kg/sqm
Floor
Second floor live load:
150kg/sqm
Roof
Wind load for roofs
120kg/sqm
Stairs
700mm clear width
200mm rise
200mm rine
FIREWALL EXTENSIONS
Above the roof line
400mm
FIREWALL EXTENSIONS\
Under the eaves
300mm
FIREWALL EXTENSIONS
From the building edges
600mm
NATIONAL ROADS OR PUBLIC HIGHWAYS
2.40M BELOW GRADE
MAY PROJECT 300MM
PUBLIC SIDEWALKS
500MM INTO THE SIDEWALK
600MM BELOW GRADE
CLEARANCE OF SERVICE DROPS
2.50m
CLEARANCE OF SERVICE DROPS
3m
CLEARANCE OF SERVICE DROPS
1m
CLEARANCE OF SERVICE DROPS
5.50M