Which is a purpose of the CAR system?
maintain CTMT bulk air temperature suitable for personnel and equipment
Following a Rx cooldown, the reactor containment is re-pressurized to atmospheric pressure. Which containment ventilation subsystem provides the flow path for this function?
containment purge air system
Which of the following describes the valve lineup for emergency breaking of containment vacuum?
CTMT purge inlet/outlet isolation (3HVUCTV33A/B) open
CTMT pressure test line isolation (3HVUV5) open
CTMT atmos suction isolation (3HVU-V6) open
Which of the following containment ventilation system components is located outside of containment?
containment purge air exhaust fans (3HVR-FN4A/B)
Which of the following containment ventilation system components is located inside of containment?
containment air filtration filters (3HVU-FLT1A/B)
Which of the following CRDM cooling system fans is powered from the emergency bus(es)?
3HVU-FN2A and 2HVU-FN2B
Which of the following containment air recirculation fans is powered from the emergency bus(es)?
3HVU-FN1A and 3HVU-FN1B