Describe the containment vacuum system lineup when it is being used to remove hydrogen from containment during an accident.
one vacuum pump uses the normal flow path and other vacuum pump is lined up to supply air to containment from the AB
Which of the following statements describe uses of the containment vacuum system?
draw initial containment vacuum prior to S/U
maintain sub-atmospheric pressure in CTMT during normal ops
provide B/U means of removing combustible gases from CTMT following a LOCA
Why must the CTMT air ejector be removed form service prior to the plant reaching Mode 4?
air ejector CTMT suction isolations are boundary valves and must be locked closed