1
Q

Which of the following describes how makeup water is supplied to the PRT?

A

water is supplied from PGS tanks via the PGS pumps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What describes the reason for maintaining a nitrogen blanket on the PRT?

A

to reduce the potential for an explosive mixture of hydrogen and oxygen

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What parameter will cause the PRT vent valve to CLOSE automatically?

A

PRT high pressure only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Which paths can all be aligned to the PRT?

A

reactor vessel head vent, pressurizer PORVs, pressurizer safeties

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

A precaution in OP 3301A requires the operator to monitor the PRT during filling operations and maintain PRT less than 64.7 psia.

What is the basis for this limit?

A

prevent distortion or damage to the rupture disks

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The pressurizer level control system is designed to:

A

control level based on the Tavg program from 0%-100% power in order to maintain a constant RCS mass

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The spray valve bypass valves are throttled slightly open to provide bypass flow which prevents ________ and enhances ________.

A

spray nozzle thermal shock, boron equalization

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The purpose of the PRT system is to collect, cool, and direct for processing _______.

A

relief and safety valve discharges inside of the containment building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

How does PRT drains outlet valve respond to a changing PRT level?

A

auto close on PRT low level, to prevent lowering PRT level below min level required to quench and cool influent from the pressurizer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Which describes how activation of Block/Auto affects the operation of the PRT drains outlet valve?

A

allows AV8031 to be opened with PRT level below the high level setpoint

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Why does the discharge from the PORV and pressurizer safety valves enter the PRT through a submerged sparger pipe?

A

effectively quench and cool the influent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

The PRT level is at 65% and pressure at 20 psia. What components will be in the OPEN position?

A

reactor plant gaseous drains containment isolation (outside)
PRT vent valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

RO is starting the PRT drains transfer pump.

Why is the RO required to place and HOLD the pump control switch in “Start” until after the pump starts?

A

placing the switch in “start” causes the inside containment isolation valve to stroke open prior to the pump starting

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What transients is the pressurizer pressure and level control system designed to accommodate without a reactor trip?

A

instantaneous load changes of 10% WITH auto rod control

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Which of the following correctly describes the function of the pressurizer spray valve bypass flow?

A

minimize thermal shock to the spray nozzle, and maintain uniform water chemistry and temp in the pressurizer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What is the primary function of the pressurizer control group heater?

A

correct for small pressure variations due to ambient heat losses and continuous bypass spray flow

17
Q

the PORVs will open in response to what signals?

A

2 of 4 pressurizer pressure channels > 2350 psia

18
Q

3RCSPCV455A is leaking by and will not reseat
Block valve 3RCS
MV8000A will not close

What is potentially a consequence of this?

A

the contents of the PRT will be released to the containment atmosphere when the PRT rupture disk fails, raising CTMT temp and pressure

19
Q

How is thermal shock of the pressurizer spray line minimized when aux spray is initiated?

A

charging flow to the aux spray line is preheated in the regenerative HX

20
Q

At what pressure will the PRT rupture disks break?

A

86 to 100 psig