What are the RHR pump trips?
What are the interlocks associated with IMO-310/320 (RHR Suction from RWST)?
What are the interlocks associated with IMO-305/306 (Recirc Sump suction valve)?
What is the interlock associated with IMO-128 (ICM-129) (Loop 2 HL RHR suction valve)
What are the interlocks associated with IMO-340/350 (RHR HX to CCP suction)?
Will not open unless:
What are the interlocks associated with IMO-330/331 (RHR(CTS) spray valves)?
When will the RHR pump recirc valve open?
- Closes at 1335(1500)gpm
What does Hot Leg recirc do for the RCS?
What are the #s that the RHR safety valves lift at and what does it support?
When is RHR (CTS) Spray used?
What is the Normal Cooldown flow path for RHR? ***
What is the ECCS lineup for RHR (Cold Leg Injection)?
What is the Hot Leg Recirc flow path for RHR?
What is the Cold Leg Recirc Flowpath for RHR?
When is RHR placed into service after a Rx Shutdown?
Why is there a minimum time 5.5 hours and 7.5 hours for Hot Leg Recirc?
Why must you close RHR Loop Injection Valves prior to aligning RHR Spray?
____ valve goes to ____ instrument goes to ____ Loop. (insert “Even” and/or “Odd” as applicable
Can we run BOTH RHR Pp’s at reduced inventory?
If have air entrainment from RHR reduced inventory, how/where do you vent?
On an SI what does the CCW outlet from the RHR Hx throttle to?
What is the weak RHR pump is protected by?
The following plant conditions exist:
Assuming electrical power is available, IMO-320 _______ be opened because _______.
A. can, IMO-390 & ICM-306 are closed.
B. cannot, RWST level is too low.
C. can, ICM-306, IMO-331 & IMO-350 are closed.
D. cannot, IMO-128 & ICM-129 are open.
C. can, ICM-306, IMO-331 & IMO-350 are closed
While shifting to cold leg recirc during a LOCA, IMO-350, SI Pump Suction from West RHR Hx, will NOT open.
Which ONE of the following conditions must be established to allow IMO-350 to be opened?
A. IMO-361 and IMO-362, SI Pump Suction Cross-Ties to CCP - OPEN
B. IMO-320, West RHR pump Suction - OPEN
C. IMO-262 or IMO-263, SI Pumps Recirc to RWST - CLOSED
D. IMO-261, SI pump Suction From RWST - CLOSED
C. IMO-262 or IMO-263, SI Pumps Recirc to RWST - CLOSED