What is the C-1 Conditional?
C-1, IR Rod Stop
What is the C-2 Conditional?
- Auto and Manual Rod withdrawal stop
What is the C-3 Conditional?
What is the C-4 Conditional?
What is the C-5 Conditional?
What is the C-11 Conditional?
What does the Mismatch Rate Comparator do?
What are the Rod Ctrl Inputs?
How is the Ctrl Rod system designed?
Which control modes allow rods to move in a normal sequence with program overlap?
Where are the MG Sets powered from?
What will trip the CRD MG Set Output Bkrs?
What will trip the CRD MG Set Supply Bkrs?
- Overcurrent
What are the Pwr Cabinet urgent failures?
What is the Logic Cabinet urgent failures?
What happens if you have an urgent failure on a Logic or Pwr Cabinet?
- De-energizes lift coil and energizes stationary and movable gripper
During a power escalation, Control Bank C – Group 1 Rod B-8 dropped. At the time the event occurred, reactor power was 48% and Rod B-8 was fully withdrawn.
While recovering the rod per 1-OHP-4022-012-005, Attachment B, “Recovery By Positioning Single Rod,” a Rod Control Urgent Failure alarm occurred.
Which of the following explains why the alarm actuated?
a. A Multiplex Error has occurred in the Power Cabinet
b. An Oscillator Failure has occurred in the Logic Cabinet
c. A printed circuit card has been jarred loose from the Power Cabinet.
d. All Control Bank C – Group 2 rod lift coil disconnect switches are open.
d. All Control Bank C – Group 2 rod lift coil disconnect switches are open.
Given the following conditions:
• Unit 1 is at 100% power
• A loss of power to CRP-3 occurs
What is the effect on the Rod Position Indication (RPI) system and the procedural action necessary, if any?
a. RPI indications are maintained since backup power supply (via ELSC) automatically energized the RPI Cabinets. Operation is allowed since RPI has been restored.
b. RPI indications are lost. Dispatch an operator to manually align backup power supply (via ELSC) to energize the RPI Cabinets. Operation is allowed since RPI has been restored.
c. RPI indications are maintained since backup power supply (via ELSC) automatically energized the RPI Cabinets. The CRP-3 power feed to RPI must be restored within 4 hours.
d. RPI indications are lost. Manually initiate a Reactor Trip and verify Reactor Trip by Wide Range power and negative start-up rate since the Rod’m Bottom Lights are NOT lit.
What does the Variable Gain Unit do?
Given reactivity change at lower pwr has a smaller effect on pwr than at high power
At what speed do the shutdown banks move?
At what speed do the rod ctrl banks move in auto?
At what speed do the rod ctrl banks move in manual?
What is Differential Rod Worth?
What is Integral Rod Worth?