What are the SFP Pump trips?
If all SFP cooling was lost, how long would it take for the SFP to boil?
What is the boron concentration suppose to be maintained at in the SFP?
≥ 2400 ppm*
What is the minimum water level allowed in the SFP?
What are the power supplies for the SFP Pumps?
- 21C 12-PP-31S
How do we keep from inadvertently draining the SFP?
What does TS 3.7.14 A (Fuel Storage Pool Water Level) state?
What does TS 3.7.15 A (Fuel Storage Pool Boron Concentration) state?
What is a secondary function of the SFP system?
Where do SFP discharge lines terminate and what do they do to prevent siphoning?
What happens to SFP Cooling on a Phase ‘A’?
If U1 is providing cooling to the SFP Hx and has an SI, what happens?
When does a RWPP trip?
Load Conservation (on bus 11D)
Core Alterations are in progress on Unit 2. RCS boron concentration has been verified to be 2360 ppm (two samples analyzed).
The crew is required to …
Will x-ting between N SFP and S SFP cooling prevent boiling?
What are the important reactivity design features?
How far does the suction for the SFP pumps terminate from the top of normal water level?
What is the primary source of heat production in the SFP? A. Fission Products B. Fission Reactions C. Fuel Cladding D. Alteration Production
What is the basis behind the reactivity design features of the SFP
One misplaced fuel assembly
How far below the surface do the SFP skimmers go
6” below normal surface level
One SFP cooling loop can maintain SFP temperature below what temperature
180 deg F
What level must SFP level be maintained below
24’ 10” to prevent overflowing the wier gate
What is the basis behind the level design features of the SFP
Iodine removal