When starting the APU, how long do you wait before pressing the APU start pb after pressing the APU Master SW pb?
3 seconds
After engine start and turning off the ignition, what are the next two pb in the sequence with regards to the APU?
The APU Bleed then the APU Master SW
After switching off the APU, note that the AVAIL in green stays. It will stay for how long and why does it stay?
60-120 seconds, cool down period
the APU Master SW pb: Lights Out 2
Lights Out:
the APU Master SW pb: On position 3
On Position
the APU Master SW pb: Fault position 4
Fault position
1. In amber
2. Indicates an automatic APU shutdown has occured
3. ECAM APU Auto (Emer) Shutdown appears
4. Examples for automatic shutdown:
Fire (on ground), EGT over temp, low oil pressure, ECB failure, air inlet flap closed (many more)
APU start sequence 3
A. If APU is started using the batteries (dark cockpit): switch both on and above 25.5v
B. APU Master Switch
C. APU Start pb