A. FROM TR1
B. FROM ESS TR
C. FROM TR2
D. FROM BAT 2
A. FROM TR1
A. THE RAT IS AUTOMATICALLY EXTENDED AND POWERS THE YELLOW SYSTEM WHICH DRIVES THE EMERGENCY GENERATOR
B. THE RAT IS AUTOMATICALLY EXTENDED AND POWERS THE BLUE SYSTEM WHICH DRIVES THE EMERGENCY GENERATOR
C. THE RAT HAS TO BE MANUALLY EXTENDED
D. THE RAT IS EXTENDED AND MECHANICALLY CONNECTED TO THE EMERGENCY GENERATOR
B. THE RAT IS AUTOMATICALLY EXTENDED AND POWERS THE BLUE SYSTEM WHICH DRIVES THE EMERGENCY GENERATOR
A. AC BUS 1
B. AC BUS 2
C. EMERGENCY GENERATOR
D. STATIC INVERTER
A. AC BUS 1
A. DC BUS 1 OR BATTERIES
B. DC BUS 1, DC BUS 2 OR BATTERIES
C. DC BUS 2 OR BATTERIES
B. DC BUS 1, DC BUS 2 OR BATTERIES
A. TO BE CONNECTED IN PARALLEL
B. TO BE SUPPLIED BY ANY GENERATOR OR EXTERNAL POWER
C. TO BE SUPPLIED BY APU GEN OR EXT PWR ONLY
B. TO BE SUPPLIED BY ANY GENERATOR OR EXTERNAL POWER
A. THE RAM AIR TURBINE (RAT) IS EXTENDED
B. THE BLUE SYSTEM IS PRESSURIZED AND THE EMERGENCY GENERATOR COMES ON LINE
C. THE GREEN SYSTEM IS PRESSURIZED AND THE EMERGENCY GENERATOR COMES ON LINE SUPPLIED BY HOT BUS 2
B. THE BLUE SYSTEM IS PRESSURIZED AND THE EMERGENCY GENERATOR COMES ON LINE
A. 22 V
B. 25.5 V
C. 27.5 V
D. NO MINIMUM
B. 25.5 V
A. FOR NO MORE THAN 3 SECS
B. FOR LONGER THAN 3 SECS
C. UNTIL FAULT LIGHT GOES OUT
D. FOR NO MORE THAN 5 SEC
A. FOR NO MORE THAN 3 SECS
A. RAT IS NOT EXTENDED
B. EMERGENCY GENERATOR IS NOT SUPPLYING WHEN AC BUS 1 AND 2 ARE NOT POWERED (ABOVE 100 KTS) OR DC BAT BUS IS NOT POWERED
C. EMERGENCY GENERATOR IS SUPPLYING BUT AC ESS BUS IS NOT POWERED
D. EMERGENCY GENERATOR IS NOT SUPPLYING WHEN AC BUS 1 AND 2 ARE NOT POWERED AND THE GEAR IS RETRACTED (NOSE L/G IS UP)
D. EMERGENCY GENERATOR IS NOT SUPPLYING WHEN AC BUS 1 AND 2 ARE NOT POWERED AND THE GEAR IS RETRACTED (NOSE L/G IS UP)
A. AC BUS 1 AND 2 ARE NOT POWERED AND EMERGENCY GENERATOR IS AUTOMATICALLY CONNECTED
B. AC BUS 1 IS POWERED BY THE GEN 2 BECAUSE THE GEN 1 IS DEACTIVATED
C. AC BUS 1 IS POWERED BY THE GEN 2 BECAUSE THE GEN 1 LINE CONTACTOR IS OPENED
D. AC BUS 1 IS NOT POWERED BECAUSE THE GEN 1 LINE CONTACTOR IS OPENED AND TRANSFER CONTACTOR IS NOT CLOSED
C. AC BUS 1 IS POWERED BY THE GEN 2 BECAUSE THE GEN 1 LINE CONTACTOR IS OPENED
A. ON THE SCAM ELEC PAGE
B. ON THE ELEC OVERHEAD PANEL
C. THERE IS NO INDICATION
B. ON THE ELEC OVERHEAD PANEL
A. AC BUS 1
B. AC BUS 2
C. STATIC INVERTER
A. AC BUS 1
A. YES
B. NO
A. YES
A. ALWAYS
B. WHEN A/C IS IN FLIGHT AND ON BATTERIES ONLY
C. WHEN ONE MAIN GENERATOR FAILS
B. WHEN A/C IS IN FLIGHT AND ON BATTERIES ONLY
A. THE RAT IS EXTENDED
B. THE EMERGENCY GENERATOR IS ACTIVATED
C. NOTHING
A. THE RAT IS EXTENDED
A. SINGLE-PHASE 115 V - 400 HZ AC. CURRENT
B. THREE-PHASE 115/200 V - 400 HZ AC CURRENT
A. SINGLE-PHASE 115 V - 400 HZ AC. CURRENT
A. APU AND ENG START + AC ESS BUS
B. ENG START + AC ESS BUS + AC ESS SHED BUS
C. ENG START
A. APU AND ENG START + AC ESS BUS
A. YES
B. NO
A. YES
A. YES
B. NO
A. YES
A. THE APU GENERATOR
B. THE OTHER COMPUTER
A. THE APU GENERATOR
A. YES
B. NO
A. YES
A. HOT BUS 2
B. ESS TR
C. BOTH
A. HOT BUS 2
A. HOT BUS
B. ESS TR
C. BOTH
B. ESS TR
A. SPEED
B. VOLTAGE
C. FREQUENCY
A. SPEED