1
Q

Which of the following will cause a running condenser air removal pump to automatically trip?

A

respective suction valve AOV22A/A not fully open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

How are the condenser air removal pumps protected from cavitation?

A

a vacuum breaker is installed at the pump suction which limits internal vacuum

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What signal causes the SJAE discharge isolation valves AOV36A/B to open?

A

SJAE steam supply pressure greater than 135 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Where would you observe the water level in the condenser vacuum breaker loop seal of MOV20A?

A

from the turbine deck, climb down to the small mezzanine to the west of the #1 low pressure turbine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the cooling medium for the condenser air removal system (ARC) steam jet air ejector inter-condensers and after-condensers?

A

condensate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

The control switch for 3ARC-P1A (mechanical condenser air removal pump) is placed in the start position. Which of the following will prevent it from starting?

A

seal water flow = 50 GPM

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the normal and alternate discharge path for the SJAE exhaust?

A

normal- U3 gaseous waste system to the stack
alternate- TB at the SJAE’s

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Which of the following is not a purpose of the condenser air removal system?

A

removes air and non-condensable gases from the feedwater heaters

How well did you know this?
1
Not at all
2
3
4
5
Perfectly