GMO Flashcards

(16 cards)

1
Q

Why must hydrogen pressure be less than 8 PSIG in this lineup?

A

prevents hydrogen from escaping through the seals

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

When generator hydrogen is less than 5 psig, and the gen seal oil system is operating, what occurs?

A

seal oil float trap bypass must be opened to prevent flooding the main generator internals with oil

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Plant at 30%

Gen core mon level hi
Reads 35%
Depress “Filter” PB

What action is the crew required to take?

A

manually trip turbine if reading returns to normal when the “FILTER” button is pressed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Identify what would likely cause a high level in the hydrogen detraining tank.

A

drain side float trap is stuck closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How should you re-initiate TPCCW flow to the coolers as you start up the system?

A

initiate flow slowly. Prevent thermal cycling of HX components

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Main seal oil pump and emergency seal oil pump have tripped. What is the max allowed hydrogen pressure in the generator?

A

8 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When purging the main generator of hydrogen, why is CO2 used as an intermediate gas, instead of purging directly with air?

A

hydrogen and CO2 do not create an explosive mixture

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

At what main seal oil pump discharge pressure will the generator emergency seal oil pump auto start?

A

105 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What statement best defines the purpose of the main generator seal oil system?

A

maintains main generator hydrogen pressure and purity by keeping hydrogen from leaking out and air from leaking in

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Why is there a CO2 connection into the main generator machine gas supply headers?

A

to provide for purging out the air or hydrogen within the generator casing to prevent combustible mixture from existing in the generator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What function does the emergency seal oil pump have?

A

provides emergency backup to supply oil to the main generator seals on a loss of main seal oil pump discharge pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What would cause the emergency seal oil pump to auto start?

A

main seal oil pump stopped or low main seal oil pump discharge pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The main generator core monitor:

A

provides indication of main generator overheating by monitoring for products of decomposition

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The seal oil float trap is bypassed to prevent which of the following?

A

flooding the main generator internals with lube oil

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the purpose of the aux detraining section of the turbine lube oil system?

A

remove hydrogen from the oil prior to its return to the turbine lube oil reservoir

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

100% power

GEN CORE MONITOR LEVEL HI alarm
local trace shows rapid drop from 90% to 5%
PEO presses “FILTER”
Reports trace returned to 90%

What action is required to take?

A

trip reactor and go to E-0 since indication of generator overheating exists