Chapter 13 Flashcards

special hazard rec (52 cards)

1
Q

Which type of foam system method extinguishes a fire by intervening between the fuel and the fire?

A

Separating

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The stage of foam formation that mixes water with foam liquid concentrate is:

A

proportioning.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Wet-chemical fire extinguishing agents are delivered to the hazard area in the form of a:

A

spray.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Which class of fire involves energized electrical equipment?

A

Class C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Which foam proportioner is the most common type of built-in proportioner installed in mobile fire apparatus?

A

Around-the-pump proportioner

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the greatest concern for extinguisher reliability?

A

Temperature of the environment

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Which dry-chemical agent is also known as ordinary dry chemical?

A

Sodium bicarbonate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Which foam proportioner is one of the most reliable methods of foam proportioning?

A

Balanced pressure proportioner

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Which type of foam fire extinguishing system is wheel mounted and may have a water supply connection capability?

A

Mobile

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Which of the following tasks regarding dry-chemical systems is an Inspector I MOST likely to be required to perform?

A

Inspect new installations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Which type of clean system agent is no longer produced but may still be in service?

A

Halon

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When rapid fire extinguishment is required and reignition is unlikely:

A

dry-chemical systems are used.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

The special-agent fire extinguishing system most effective on fires in commercial cooking equipment that produces grease-laden vapors is a:

A

wet-chemical system.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When it comes to fire extinguishers, inspectors are responsible for:

A

providing information and recommendations for training.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

How often do all components of clean-agent systems need to be inspected by qualified personnel?

A

Annually

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

The general method for locating and distributing extinguishers consists of:

A

classifying occupancies based on hazard levels.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Who is responsible for keeping accurate records of fire extinguisher inspections?

A

Owner/occupant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Which dry-chemical system component may contain both the agent and the pressurized expellant gas?

A

Storage container

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Which type of dry powder agent is sodium chloride (salt) based?

A

MET-L-X®

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

The general category of fire extinguishing agents that effectively leaves no residue is a:

A

clean agent system.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Who is responsible for verifying to the inspector that dry-chemical systems are maintained and serviced?

A

Qualified individual

22
Q

In addition to the clean-agent system inspections and tests, what else must be inspected annually?

A

Protected enclosure

23
Q

Which foam expansion rate is used primarily to extinguish fires involving liquid fuels?

24
Q

What is the biggest disadvantage to dry-chemical systems?

A

Require extensive cleanup

25
Which type of special-agent fire extinguishing system is used for combustible metal fires?
Dry-powder systems
26
Which fire extinguisher agent extinguishes primarily through a smothering action?
Carbon dioxide (CO2)
27
Clearance between the bottom of the extinguisher and the floor should never be less than:
4 inches (100 mm).
28
The system used when water alone may not be an effective fire extinguishing agent is a:
foam system.
29
How are portable fire extinguishers classified?
Type of fire they will extinguish
30
Which fire extinguisher agent is especially suitable for controlling fires outdoors?
Dry chemical
31
What percentage of finished foam is water?
94% to 99½%
32
NFPA® 10 recommends portable fire extinguishers be inspected:
monthly.
33
In a clean-agent system, the quantity and pressure of the clean agent must be checked:
semiannually.
34
How often are dry-chemical agent storage containers less than 150 pounds (75 kg) required to be hydrostatically tested?
Every 12 years
35
What is critical to total flooding applications of carbon dioxide (CO2) systems in order for them to be effective?
Room integrity
36
How often should CO2 agent cylinders be checked and changed if necessary?
Semiannually
37
Which type of fire extinguisher stores expellant gas and extinguishing agent in a single chamber?
Stored-pressure extinguisher
38
Portable fire extinguishers are rated by:
intended use and extinguishing capability.
39
How often should valves and alarms attached to foam systems be checked?
Semiannually
40
Which fire extinguisher agent is subject to freezing if not kept in a heated area or an antifreeze agent added?
Water
41
The four elements necessary to produce high-quality fire fighting foam include foam concentrate, water, mechanical agitation, and:
air.
42
Foam concentrates, foam equipment, and foam proportioning systems should be checked:
annually.
43
Which dry-chemical system component releases agent into the piping system?
Actuating mechanism
44
Which type of dry-chemical fixed application method introduces a concentration of agent into a closed area?
Total flooding
45
Which foam expansion rate is useful as a space-filling agent?
High
46
What kind of test is required every five years for clean-agent storage containers?
Hydrostatic
47
What is the most important factor in determining the distribution of Class B extinguishers?
Travel distance to the hazard
48
Which foam proportioner allows for automatic proportioning over a wide range of flows and pressures and does not depend on an external power source?
Pressure proportioning tank system
49
Who should perform maintenance and testing on CO2 extinguishing systems?
Licensed representatives of the system manufacturer
50
The special-agent fire extinguishing system that is extremely cold and can freeze exposed skin is the:
carbon dioxide (CO2) system.
51
What is required for a special-agent extinguishing system to be considered successful?
It must completely extinguish the fire
52
How are special-agent fire extinguishing systems classified?
By the type of fire they will extinguish