Seal injection flows
ITS, Normal, Expanded?
Auxiliary Spray Valve (CVC-311)
Fails? Max Delta T?
Fails shut
320°F between PZR and charging Temps to protect the spray nozzels
Total volume of Boric Acid available in both Boric Acid tanks shall be maintained at what?
≥3080gallons, allows use to get to cold shutdown
What is the ppm and temp for boric acid in the BAST?
20,000 to 22,500 ppm greater than 145°F
When you loose IA to Charging pumps what happens to them?
(assume no backup)
Fail to max speed