Auto Rod Control system is designed to
Keep Tavg consistent with Tref.
Uses Tavg and compares to First stage turbine pressure
When in AUTO is there any OUTER motion?
NO OUTER MOTION IN AUTO
Rod Control
Auto Rod Contorl system is designed to do what?
REstore program Tavg folowing a scheduled or transient step shange in load of 10% or ramp change of 5% per minute within the range of 15-100% power
1 step is how much movement?
5/8 inch
ITS Maximum time for rod drop?
1.8 seconds
CRDM Out Sequence
CRDM in sequence
How long does it take for a single step to be performed?
780 milliseconds (.78 seconds)
Rod Drive Motor Generator
Powered from, output?
480V Bus 2B/3
Outputs 260V at 58.3 hertz
If a bank is individually selected to move, what does this do?
No bank overlay. Must be returned to the position held before individual banks were moved.
Reading Power Cabinets
1AC is?
Group 1 in Shutdown Bank A
Group 1 in Control Bank A
Group 1 in Control Bank C
Reading Power Cabinets
2BD is?
Group 2 Shutdown Bank B
Group 2 Control Bank B
Group 2 Control Bank D
Power Cabinet Urgent Alarm does what?
Power Cabinet Urgent alarm caused by?
MR. LLP
Can you still move rods on a Urgent Power Cabinet alarm?
Not on effected cabinet but if you select an infidivual bank you can move that bank but you loose designed overlap
If you misposition a rod bank out of overlap what must be done before returning to MANUAL OR AUTO on the selector switch
Whatever bank was moved must be moved back to correct postion per procedure
Power Cabinet Non-Urgent alarm does what?
Loss of Power supply causes an urgent alarm if INWARD rod motion is demanded. (causes a logic error)
If OUTWARD rod motion is demanded will ratchet or drop
We place rods in manual and do not attempt any motion until repairs comp
A Logic Cabinet Urgent alarm does what?
A Logic Cabinet Urgent alarm is caused by?
SLO
Power Cabinet and Logic Cabinet non urgent alarms are caused by?
Power supply failure
Overlap works how?
Total of 602 steps
Rod Control Logic compares what?
Median Tavg to Tref
How much difference does Tavg have to be above Tref before Rod movement? when does movement stop?
1.5 degrees F. starts Rod insertion, once Tavg and Tref are within 1 degree of each other Rod movement stops
Rod Insertion Limits setpoint comes from?
Linear function of Median Delta T