System description
minimum battery voltage
BUS TIE in AUTO
Allows any single generator or EXT PWR to run the entire system
electrical priority logic
“GEAR B”
G enerators
E XT PWR
A PU
R AT
B atteries
circuit breaker colors
Green - monitored
Black - not monitored
Red Collar - prevents flight crew from pulling
GALLEY pb FAULT light
at least one generator load is above 100% rated output
BAT pb FAULT light
battery charging current outside limits,
BAT contactor opens
buses powered by the EMER GEN
normal power source of the DC BAT BUS
DC BUS 1 through the DC tie contactor
When are the batteries connected to the battery bus?
RAT drop
GEN 1 LINE SMOKE
Smoke has been detected in the avionics ventilation ducting.
Expect ECAM warning(s) and EXTRACT and BLOWER FAULT lights
GEN 1 LINE pb OFF
AC ESS BUSS FEED
AC ESS BUS is normally powered by AC BUS 1 and automatically switches to AC BUS 2 with
the loss of AC BUS 1
ALTN comes on when manually selected. Manual selection switches power source to
AC BUS 2.
FAULT indicates that AC ESS is not powered
IDG fault light
“HOTLOP”
H igh
O il
T emperature
L ow
O il
P ressure
RAT & EMER GEN red FAULT light
If the ECAM directs a pilot to select GEN 1 LINE off, what will that do?
GEN 1 line contactor opens (white OFF light will light)
AC BUS 1 will be powered by GEN 2 via the bus tie contactors
GEN 1 will however still power one fuel pump directly in each wing tank
What flight deck lighting is available if normal electrical power is lost?