Describe the Mode 1 L/U for control room vent.
Include % recirc and m/u
normal L/U
Describe the Mode 2 L/U for control room vent.
Include % recirc and m/u
include any drawbacks
fire mode
air conditioning not rated for 100% flow => temp will rise in CR
Describe the Mode 3 L/U for control room vent.
Include % recirc and m/u
include any deficiencies
toxic gas
since recircing air O2 is slowly depleted=> limited time
Describe the Mode 4 L/U for control room vent.
Include % recirc and m/u
Pressurization
Describe actuation logic for CR ventilation into Mode 4
Describe sequence for starting fans for CR ventilation if LOCA is on U-1
LOCA on U-1 (Phase A or RE-25/26)
What areas/ compartments make up the Control Room Envelope (CRE)?
Why is it important to maintain the CRE boundary?
if boundary not maintained, design basis of limiting control room personel to 5 Rem whole body during durration of DBA is not ensured.
(CRVS) What will block Mode 1 and 2 operation?
Durring CRVS mode changes are the Modes always matched between control rooms (U-1 and U-2)?
What must not be done if both Units CRV are selected for Bus H?
Dont select one unit from normal P.S. and other unit from alternate P.S. (they will both be powered from same bus)
Then
You must declare one Unit CRV inoperable