Describe LCV-459 & 460
Norm value regen hx
Letdown inlet
Letdown outlet
Charging inlet
Charging outlet
545 degrees
290
130
480
Describe Orifice isolation valves CVCS-8149 A, B, & C
Describe CIV CVCS-8152
Describe HCV-133
Describe Letdown hx
Describe PCV-135
Describe TCV-149
Describe demineralizers MB (2) Cat bed (1) Deborating (2) Filters (2)
MB- maintain RCS chemistry(remove unwanted ions)
CB- reduce RCS pH by removing Li+ ions
DB- remove Boron when [B] so low it would take a lot of water to dilute (1-1 is MB used during forced O2)(1-2 is anion bed used to remove boron)
Ltdn filter- collects resin fines & other particulates
How does temperature affect resin beds affinity for boron
boron sweats!
Purpose of Zinc injection system
Describe Argon injection
Describe LCV-112A
Purposes of VCT
LT-112 outputs
LT-114 outputs
Describe CCP’s
P.S.
1-1
1-2
1-3
Auto starts on ECCS CCP
Manual start
SI
XFR to diesel
(Auto start will not wait for oil Press)
Manual will not start in man if oil Press < 9psig
Trips on ECCS CCP
O.C.
Xfr to diesel (load shed)
CCP 1-3
Trips
Air cooled
UV
O.C.
Xfr to diesel
What will cause CCP suction to swap from VCT to RWST?
LCV-112B, 112C close
8805A, 8805B open
Both LT-112 & 114 = 5% Lvct
SI
As soon as one RWST valve is f.o., VCT valves will shut
Describe purpose, interlock and p.s. for 8107 and 8108
Close on SI
Isolates charging(downstream of HCV-142)
8107-F, 8108-G
Motor operated CIV
Different possible loads on seal water hx?
During SI
Seal return
Excess letdown
CCP recirc
Only CCP recirc