What is the minimum CW temperature for the Main Condensers and why
65*F
fatigue stress on tubes
What is the normal storage volume of the condenser hotwells
100,000 gallons
4 minutes of full flow
When do the condenser equalizing ducts blow
30*F differential temperature between shells
When do the condenser equalizing ducts blow
30*F differential temperature between shells
When can you open the condenser vacuum breakers be opened
Main turbine <1200 rpm
What is the power supply for Hotwell makeup vlvs
NKN-D41
What is the normal Condenser Hotwell levels and why
How does the Hotwell makeup vlv fail
Loss of Power - Closed
Loss of Air - Closed
Lo-Lo CST lelvel - Closed
What will Cause hotwell draw off vlv to Auto Close
What are the power supplies to the Condensate pumps
A - NBN-S01
B - NBN-S01
C - NBN-S02
What worthless feature does the Condensate pump discharge vlvs have
Push to stop button to stop vlv travel mid cycle
Which hotwells do the Condensate pumps suck off
A - 2A/B/C
B - Either
C - 1A/B/C
What are the Condensate pump trips
What are the power supplies to the Condensate pump mini-flows
A - NNN-D12
B - NNN-D11
C - NNN-D12
How do the Condensate mini-Flows fail what problem could that cause
- Could result in Low MFP suct. press.
What signals are provided by CDN-V191 Condensate Demin Inlet isolation
- Modulate Permissive for 195 Demin bypass
How large of a CW leak can Condensate Demins control/ handle
< 1 gpm
When does the Condensate Demin Bypass vlv open
- D/P >55 psi
How does the Demin Bypass vlv CDN-V195 fail/ Auto actuate
Auto Opens
When can long path recirc isolation vlv SGN-HV-46 be opened and how is that accomplished and why