CVCS Charging Flashcards

(32 cards)

1
Q

What is the power supply for CHN-501

A

PHA-M35 via passthrough in NHN-M72

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What automatic functions are there for CHN-501

A

-Will auto close on Lo-Lo VCT level 5%
-Will auto open when VCT Lo-Lo resets AND CHN-536
is closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What does the CH provide to CVCS

A
  • RCS makeup
  • RCP Seal Inj.
  • PZR aux spray
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Where can the CH pumps take suction from?

A
  • VCT via CHN-501
  • Blended Makeup via CHN-527
  • Directly from BAMP via CHN-514
  • RWT Gravity Feed from CHN-536
  • Alternate Suct. from RWT via CHB-327
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Where can the CH pumps discharge to?

A

-Charging header
-HPSI A cold leg
-HPSI B hot leg
(a cold, be hot)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How are the Charging pumps protected from cavitation damage

A

Low Suction press trip at 13 psia (CH pump will be anti-pumped after trip)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What are the modes of operation for the CH pumps

A
-Auto-After-START
     Does not respond to PLCS
-Auto-After-Stop
     Operated by the PLCS
-Stop
     Opens the pump breaker
-Pull To Lock
     Prevents the pump from running under any cond.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

How do you clear a CH pump anti-pump condition

A

Take the Hand switch to STOP

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What HU trap is associated with CH pump running lights

A

The lights are breaker position and does NOT mean the pump is running

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the power supply for CH indicating lights

A

PK

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Following a LOP what is the status of the CH pumps
Always Running-
Normal Running-
STBY-

A
  • Anti-Pump
  • Anti-Pump
  • No effect
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Following a LOOP what is the status of the CH pumps
Always Running-
Normal Running-
STBY-

A
  • Anti-Pump
  • Restarted by PLCS
  • no effect
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Following a SIAS what is the status of the CH pumps
Always Running-
Normal Running-
STBY-

A
  • No Effect
  • No Effect
  • No Effect
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Following a LOP W/ SIAS what is the status of the CH pumps
Always Running-
Normal Running-
STBY-

A
  • Load Shed Will restart after 40 sec. b/c SIAS
  • Load Shed Will restart after 40 sec. b/c SIAS
  • Controlled by PLCS
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Following a LOOP W/ SIAS what is the status of the CH pumps
Always Running-
Normal Running-
STBY-

A
  • Load Shed Will restart after 40 sec. b/c SIAS
  • Load Shed Will restart after 40 sec. b/c SIAS
  • Controlled by PLCS
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

How long can CH pumps run without seal water

A

Up to 50 hours

17
Q

What are indications of gas binding of a CH pump

A
  • Loss of pump suction
  • Flow/press fluctuations
  • Isolation of letdown due to Regen HX temp.
18
Q

What is CHN-524, what is its normal position and why

A
  • Charging to CNTMT isolation valve
  • Normally OPEN with power removed
  • commitment to NRC to prevent isolating Aux Spray
19
Q

What is the purpose of CHN-239

A

prevents the loss of Aux Spray if CHN-240 fails open

20
Q

What is the purpose of CHN-240

A

maintains CH header backpressure for Aux Spray approx. 105 psid

21
Q

What is the purpose of CHA-205 & CHB-203

A

Aux Spray valves provide PZR press. control when normal control is not available

22
Q

What is the power supply for Aux Spray valves

23
Q

What auto action is associated with Seal Inj. Iso. valve CHN-231

A

Closes on Temp Hi/Lo 150 or 70*F

24
Q

What is the Fail position for CHN-241, 242, 243, 244 Seal inj. flow control valves?

A

Fail OPEN on loss of:

  • Air
  • Power to solenoids (NKN-D42)
  • Power to flow controller (NNN-D11/12)
25
What HU trap is associated with Seal Inj. flow controllers
They are reverse acting, | 100% output closes the valve
26
What will cause CHA/B-505/506 Seal Bleed off CNTMT iso valves to close
- Loss of Air - Loss of power (PK) - CSAS (can be overridden)
27
At what temperatures does the Regen HX alarm, & Isolate
- Alarms at 395*F | - Isolates at 413*F
28
Describe the relation b/w CH flow, LD flow, and Bleedoff flow
``` CH = LD + Bleedoff 88 = 76-ish + 12-ish ```
29
What SESS alarms are associated with CH
CHA/B-505/506 will cause a Blue SEAS light if not FULLY closed with actuation signal present
30
What is required to make CH pumps "Functional" online
At least 2 charging pumps shall be functional | -Enter TLCO - Immediately
31
What is required to make CH/ boration "Functional" shutdown
At least 1 CH pump OR 1 HPSI OR 1 LPSI shall be functional -Suspend Core Alts - Immediately -Suspend (+) reactivity ops - Immediately
32
What is required for Aux Spray to be "Functional"
Both Aux Spray Valves shall be Functional | -Enter TLCO - Immediately