What is the purpose of EW
What is the purpose of EW
How is leakage into or from EW detected
What does EW Cool
How does EW act as an intermediate system?
EW pressure AT THE EW HX is less than SP press
How is NPSH for the EW pump accomplished
- N2 cover gas is for oxygen control NOT NPSH
What will Auto start EW?
SLACCC
What will Auto Stop EW
- Brkr Trip
When does EW Surge tank makeup normal come in
Open - 22”
Close - 26”
What are the EW surge tank Hi/Lo levels
Hi - 50” Alarm
Lo - 18” Alarm
LO - 17” A Train x-conn auto closes
LoLo - 14” Makeup isolates
What is the Refrigerant Head Pressure Control Vlv and what does it help with
What is the MOST limiting postulated EW condition
17% degraded EW pump while concurrently aligned to SFP
What are the NC priority loads
What additional IN FIELD action is required when EW is aligned to NC Priority loads
Throttle SDC HX until RCP NC Flow alarms clear
How is NC Restored to NC Priority loads after being supplied by EW
- This will temporarily secure cooling flow again
What is the most limiting component for supplying cooling flow to NC Priority loads
What is required to restore EW to “Operable” after supplying SFP cooling
a Flow Balance must be performed
What Auto Features do the Train A EW - NC x-connect vlvs have
Auto close on:
SIAS can be overridden to reopen, Lo level CANNOT
What is required for EW to be “Operable”
Modes 1-4
2 Trains of EW Shall be operable
2 trains inop: 1 HOUR
- Restore at least 1 train
What Special Feature is required by TLCO for MOV thermal overload protection
TLCO 3.8.102 requires the thermal overload for MOV’s on safety related equipment to be bypassable to ensure safety functions are performed
What is the effect of isolating the SDC HX
Isolating EW to the SDC HX inops the SDC HX and EW