What type of detector is used for the Gas Process Monitors?
Beta scintillation detector for low range detection
When high range detection is needed a GM detector is used
What type of detector is used for the Liquid Process Monitors?
Gamma scintillation detector for low range detection.
When high range detection is needed a GM detector is used
What automatic actions occur on a Trip 2 signal on (1EMF-15, 2EMF-4) Fuel Storage Pool Area?
Automatically stops new fuel elevator from being raised
What automatic actions occur on a Trip 2 signal on (1EMF17, 2EMF-2) - Reactor Building Refueling Bridge?
Actuates containment evacuation alarm below P-6. This auto action is blocked when both source ranges’ high flux trip is blocked.
What automatic actions occur on a Trip 2 signal on 1(2) EMF31 - Turbine Bldg. Sump?
Stops automatic and manual operation of the sump pumps in the unit related sump.
An override switch on local sump pump control panel allows manual operation of the pumps.
What automatic actions occur on a Trip 2 signal on 1(2) EMF33 - Condenser Air Ejector Exhaust?
What automatic actions occur on a Trip 2 signal on 1(2) EMF35/36L Unit Vent Particulate/Gas Monitor?
What automatic actions occur on a Trip 2 signal on 1(2) EMF38 - Containment Particulate?
What automatic actions occur on a Trip 2 signal on 1(2) EMF39 (L) - Containment Gas - Low Range?
What automatic actions occur on a Trip 2 signal on 0EMF41 - Aux Bldg Ventilation?
What reading on 0EMF41 - Aux Bldg Ventilation would require conduct a site assembly?
> 1x10^6 CPM
What automatic actions occur on a Trip 2 signal on 1(2) EMF42 – Spent Fuel Pool Ventilation?
Aligns VF to filter mode
What automatic actions occur on a Trip 2 signal on 0EMF49 (L) - Liquid Waste - Low Range?
Closes 1WL-124 (Waste Monit Tnk Pmps Disch)
What automatic actions occur on a Trip 2 signal on 0EMF50L - Waste Gas Discharge - Low Range?
Closes 1WG-160 (WGDT Outlet to Unit Vent Isol)
What automatic actions occur on a Trip 2 signal on 1EMF52 – Clean Area Floor Drain?
Realigns Floor Drain Sump D(C) Pump discharge from the turbine building sump to the ND & NS room sump
What automatic actions occur on a Trip 2 signal on 1(2) EMF53A & B – Containment Train A(B)?
1(2) EMF-53A –
- Closes 1(2) WL-825A (Cont Sump Pmps Disch Cont Isol)
- Closes 1(2) WL-867A (VUCDT Cont Isol)
1(2) EMF-53B –
- Closes 1(2) WL-827B (Cont Sump Pmps Disch Cont Isol)
- Closes 1(2) WL-869B (VUCDT Cont Isol)
What automatic actions occur on a Trip 1 signal on 1(2) EMF54HH – Unit Vent Gamma Hi-Hi Range?
Trips the 1(2) EMF35 & 36 sample pump
What automatic actions occur on a Trip 2 signal on 0EMF-55 A & B - Tech Support Center Monitor?
Isolates TSC outside air intakes by closing
What automatic actions occur on a Trip 2 signal on 0EMF-57 - Waste Monitor Tank Building Liquid Discharge Monitor?
Closes 1WL-X28 (MTB Disch to RL Isol)
If 1(2) EMF53A & B – Containment Train A(B) are non-functional, how is containment radiation measured?
RP would monitor the contact dose rate at the center of the outside airlock door.