The fuel storage and handling areas are designed to meet what major criteria?
The Spent Fuel Pool is designed to ensure that Keff stays below what value if fully flooded with unborated water (RN assured make-up)?
Keff < 1.0
The Spent Fuel Pool is designed to ensure that Keff stays below what value if flooded with water borated to a minimum of 200 ppm?
Keff < 0.95
The New Fuel Storage Vault is designed to ensure a maximum Keff of what?
What occurs on a Trip 2 on 1EMF-15/2EMF-4 (Fuel Bridge Area Monitor)?
Prevents New Fuel elevator from moving in up direction
What occurs on a Trip 2 on 1EMF-17/2EMF-2 (Reactor Building Refueling Bridge Monitors)?
(SFP & RB) The Gripper tube must be at what position to allow bridge or trolley to operate?
(SFP) Bridge and trolley are electronically interlocked to limit the mast to a path of travel that prevents collision with what?
Spent fuel pit walls/lights.
(SFP&RB) To enable operation of the hoist in the up or down direction, the gripper must be in which condition?
(SFP) To operate the gripper (Grab or Release a fuel assembly), weight indicator must read less than what?
1200 lbs
(SFP&RB) Hoist will not operate in the up direction if there is an overload condition of what?
(SFP&RB)Hoist will not operate in the up direction if load cell indicates greater than what and gripper is disengaged?
1200 lbs
(SFP&RB) Hoist will not operate in the down direction if what condition exists (1780 lbs West. Or 1850 lbs B&W)?
(SFP) What condition will prevent the Hoist from operating in the down direction? (Less than 500 lbs. on weight indicator).
(SFP) What condition will prevent the East Auxiliary Hoist (2 ton) from operating in the up direction?
(SFP &RB) In what mode is the Bridge, Trolley, and fuel hoist mutually interlocked such that only one drive is operable at a time?
Manual mode
(RB) To enable operation of the fuel gripper solenoid there must be indication from the load cell that a low load condition of what exists?
less than 500 lbs
What two conditions will allow the Interlock Bypass Switches to be used?
Approved Procedure says to
or
Permission is obtained from the Refueling SRO
What are the required actions of LCO 3.9.1 (Boron Concentration) if Boron concentration not within limit of the COLR?
What is the Bases for the required boron concentration in LCO 3.9.1 (Boron Concentration)?
Ensure that the keff of the core will remain less than or equal to 0.95 during the refueling operation. Hence, at least a 5% delta k/k margin of safety is established during refueling.
What is the Basis for the great than or equal to 23 feet water level in the Refueling cavity per LCO 3.9-6 Refueling Cavity Water Level?
Retain iodine fission product activity in the water in the event of a fuel handling accident
What are the required actions of LCO 3.9-6 Refueling Cavity Water Level if Refueling cavity water level not within limit?
Per SLC 16.9-17 Refueling Operations - Decay Time, how long must the reactor be subcritical before movement of irradiated fuel is allowed?
Great than or equal to 72 hours
What is the bases for waiting greater than or equal to 72 hours prior to moving irradiated fuel per SLC 16.9-17 Refueling Operations - Decay Time?
Ensures that sufficient time has elapsed to allow the radioactive decay of the short-lived fission products