WL Flashcards

(19 cards)

1
Q

What is the purpose of The Liquid Waste System?

A

Collects, segregates, and processes all radioactive and potentially radioactive liquids generated in the plant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the inputs to the Steam Generator Drain Tank (SGDT)?

A
  • Waste Evaporator Feed Tank (WEFT)
  • Floor Drain Tank (FDT, alternate pathway)
  • TB Sumps (when Contaminated)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the inputs to the Reactor Coolant Drain Tank (NCDT)?

A
  • NCP’s #2 and #3 seal leakoffs.
  • Piped up valve leakoffs.
  • Excess Letdown Heat Exchanger effluent when aligned to NCDT.
  • Misc. equipment drains
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the normal inputs to the Ventilation Unit Condensate Drain Tank (VUCDT)?

A
  • Upper & Lower Containment Unit Vents
  • Incore Instrumentation Room AHUs
  • ICE Melt (major outage input)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What signals will close WL-867A/WL-869B (VUCDT Containment Isol)?

A
  • Phase A Signal
  • High Radiation (Trip 2) from EMF-53A/B (Containment Area Monitor).
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What EMF monitors releases from the Recycle Monitor Tank (RMT) and what valve closes on a trip 2 signal?

A

EMF-49 trip 2 closes 1WL-124

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Can a release from the Recycle Monitor Tank (RMT) be performed if RN is aligned to the SNSWP?

A

No, to perform a release from the RMT, RN must be aligned to Lake Wylie.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What EMF monitors the Non-Contaminated Area Floor Drains (Clean Drain sumps (C & D)) and what happens on a trip 2 signal?

A
  • EMF-52 (Clean Floor Drain Sump) trip 2 will divert the flow from the Turbine building sump to the ND/NS sump.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What EMF monitors the CA pump room sumps and what happens on a trip 2 signal?

A
  • EMF-52 (Clean Floor Drain Sump) trip 2 will divert the flow from the Turbine building sump to the ND/NS sump.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

If the ‘A’ CAPT Sump Pump becomes non-functional what is impacted?

A

The CAPT is inoperable and the SSF is non-functional.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

If the ‘B’ CAPT Sump Pump becomes non-functional what is impacted?

A

The CAPT inoperable

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What signals will close WL-825A/WL-827B (CONTAINMENT SUMP PUMPS DISCH CONTAINMENT ISOL)?

A
  • Phase A Signal
  • High Radiation (Trip 2) from EMF-53A/B (Containment Area Monitor).
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

If EMF-52 (Clean Area Floor Drain Monitor) trip 2 is reset, will the flow automatically realign to the Turbine building sump?

A

Yes, the alarm shall not be reset without RP permission

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What occurs on a trip 2 on 0EMF-49 (Liquid Waste Discharge Monitor)?

A

Closes 1WL-124

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What occurs on a trip 2 on EMF-31 (Turbine Building Sump Radiation Monitors)?

A

Stop all affected TB Sump pumps

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

How many times can you restart a release being monitored from 0EMF-49?

A

Twice, if the release is auto terminated a third time the Liquid Release Evolution must be secured and the Liquid Waste Release Permit closed out.

17
Q

What is the limit for the quantity of radioactive material contained in each temporary unprotected outdoor tank?

A

Less than or equal to 10 Curies, excluding
tritium and dissolved or entrained noble gases.

18
Q

What is the Mode of Applicability for SLC 16.6-5 Residual Heat Removal/Containment Spray Sump Pump Interlock?

A

MODES 1, 2, 3, and 4 on either Unit 1 or Unit 2

19
Q

What is the Basis for the residual heat removal/containment spray sump pump interlock?

A
  • To alert the operator to potential Emergency Core Cooling System leakage