What is the purpose of the KF (Catawba Spent Fuel Pool Cooling System)?

A

Designed to remove heat from the Spent Fuel Pool and maintain purity and optical clarity of the pool water during fuel handling operations.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the mode of Applicability for LCO 3.7.14 Spent Fuel Pool Water Level?

A

During movement of irradiated fuel assemblies in the spent fuel pool.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What SFP level is required per LCO 3.7.14 Spent Fuel Pool Water Level?

A

Greater than or equal to 23 ft (37.6 ft on 1KFP5120) over the top of irradiated fuel assemblies seated in the storage racks.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Where can the Spent Fuel Pool level be made-up from?

A

-YM (unborated water source)
-RMWST (Reactor Makeup Water Storage Tank)(unborated water source)
-RHT (Recycle Hold Up tank)(borated water source with a varying concentration)
-FWST (borated water source)
-RN system (unborated water source) is assured makeup supply

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How many gallons of water per foot are in the SFP?

A

17,000 gallons of water per foot of level.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are the bases for the great than 23 feet requirement of LCO 3.7.14 Spent Fuel Pool Water Level?

A

-Meets the assumptions of iodine decontamination factors following a fuel handling accident.
-Shields and minimizes the general area dose when
the storage racks are filled to their maximum capacity.
-Provides shielding during the movement of spent fuel.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Are the KF pumps automatically started by the sequencer following a blackout?

A

No, they get a permissive to start from load group 13, must be manually started.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What signals will close KF-101B and KF-103A (FWST to SPENT FUEL POOL)?

A

-Ss signal
-When control is shifted to the associated Auxiliary S/D panels

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What occurs on a trip 2 signal on the Spent Fuel Building Refueling Bridge Monitors (1EMF-15 and 2EMF-4)?

A

Automatically stop the new fuel elevator from being raised

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What two signals would require securing the KF Pumps to prevent pump motor overheating?

A

-Sp
-An Ss coincident with a Lo FWST signal

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Per limits and precautions of OP/1/A/6200/005 (Spent Fuel Cooling System), what is the maximum flow through purification loop with only 1 pre-filter or post filter in service?

A

265 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Per limits and precautions of OP/1/A/6200/005 (Spent Fuel Cooling System), what is the maximum flow through purification loop with 2 pre-filters and 2 post filter in service?

A

530 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Per limits and precautions of OP/1/A/6200/005 (Spent Fuel Cooling System), what is the maximum fuel pool temperature for operating the purification system with the demineralizer in service?

A

125 degrees F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Per limits and precautions of OP/1/A/6200/005 (Spent Fuel Cooling System), The maximum fuel pool temperature for operating the purification system with the KF System filters in service?

A

180 degrees F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Per limits and precautions of OP/1/A/6200/005 (Spent Fuel Cooling System), The maximum fuel pool temperature for operating the skimmer loop?

A

200 degrees F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Per limits and precautions of OP/1/A/6200/005 (Spent Fuel Cooling System), At what fuel pool temperature is the SSF non-functional?

A

Greater than or equal to 125 degrees F

17
Q

What is required actions for LCO 3.7.14 (Spent Fuel Pool Water Level) if spent fuel pool water level is not within limit?

A

Immediately Suspend movement of irradiated fuel assemblies in the spent fuel pool.
————-NOTE————–
LCO 3.0.3 is not applicable.

18
Q

What is required actions for LCO 3.7.15 (Spent Fuel Pool Boron Concentration) if Spent fuel pool boron concentration not within limit?

A

-Immediately suspend movement of fuel assemblies in the spent fuel pool
AND
-Immediately initiate action to restore spent fuel pool boron concentration to within limit
————-NOTE————–
LCO 3.0.3 is not applicable.

19
Q

What is required actions for LCO 3.7.16 (Spent Fuel Assembly Storage) if Requirements of the LCO not met.?

A

Immediately Initiate action to move the noncomplying fuel assembly to the correct location.
————–NOTE————-
LCO 3.0.3 is not applicable.

20
Q

Per SLC 16.7-17 Spent Fuel Pool (SFP) Wide Range (WR) Level Instrumentation, how many SFP WR Level Instrumentation channels shall be FUNCITONAL and when?

A

2 Whenever irradiated fuel assemblies are stored in the SFP.

21
Q

What is required actions for SLC 16.9-21 Refueling Operations - Storage Pool Water Level) if less than 23 ft of water in the SFP?

A

-Immediately suspend all movement of fuel assemblies and crane operations with loads in the fuel storage area.
AND
-With in 4 hours restore water level to within limit.

22
Q

Per SLC 16.9-21 Refueling Operations - Storage Pool Water Level), what is the bases for the minimum water level of 23 feet?

A

Ensure that sufficient water depth is available to remove 99% of the assumed 10% iodine gap activity released from the rupture of an irradiated fuel assembly