From memory, draw and label a one line diagram of the Primary Coolant System showing the following major components and system interfaces:
Draw use Triangle Notes for Standard
What is the operational design and normal operating range for the PCS Hot Legs?
Hot: 42-inch inside diameter piping
What is the operational design and normal operating range for the Pressurizer?
Maintains PCS operating pressure and compensates for changes in the PCS volume during load changes.
Water volume is sized such that the PZR:
The steam volume is such that:
What is the operational design and normal operating range for the Pressurizer Safety Valves?
Sized to limit PCS over-pressure to 110% of design pressure (2500 psia/2750 psia) following a complete loss of generator load without a simultaneous trip of the reactor.
Capacity – 230,000 lb/hr each
RV-1041 – 2500 psia
RV-1040 – 2540 psia
RV-1039 – 2580 psia
What is the operational design and normal operating range for the Power Operated Relief Valves (PORVs)?
PRV‑1042B (125V DC, D11-1), PRV-1043B (125V DC, D21-1):
Two modes of operation – LTOP and SDC
What is the operational design and normal operating range for the Quench Tank?
Receives and condenses the normal discharges from the pressurizer safety and relief valves, and prevent the discharge from being released to the containment atmosphere.
Pressure – 100 psig; NOP – 3 psig (N2 cover gas)
Temperature – 340°F; NOT – 104°F
Normal Operating Level – 75%
Water volume (800 ft3) to condense total steam mass released during a 112% to 0% reactor power swing.
Gas volume (347ft3) to limit max tank pressure after the steam release to one half of rupture disc set point of 100 psig (assumes max initial gas pressure of 10 psig).
What is the operational design and normal operating range for the Steam Generators?
U-tube Steam Generators (8,219 tubes)
Feedwater enters the S/Gs through the feed ring, mixes with recirculating water from the moisture separators and flows into the downcomer
J-tubes on the feed ring prevent draining of the feed ring during periods of no feedwater flow. Minimized water hammer during stops and starts of flow.
Steam exiting the steam generator through the steam flow restricting nozzle has a moisture content of less than 0.25% moisture at design flow rate.
Restricting nozzle limits MSLB impacts.
What are the inputs/outputs to the Quench Tank?
Inputs
Outputs
What is the operational design and normal operating range for the PCS Cold Legs?
30-inch inside diameter piping
What is the gallons per percent and volume of Pressurizer?
What are the pressurizer block valves?
(MO-1042A, MO‑1043A) provide isolation to PORVs
Controlled by 2-position CLOSE-OPEN switches:
JOG control feature in OPEN direction only – valve only travels when switch is held. Prevents inadvertent opening and allows pilot chamber pressure to slowly equalize
MO-1042A – MCC-25
MO-1043A – MCC-26
When does the Quench Tank rupture disk blow?
100 psig
a 10 psig starting pressure is assumed for time to rupture calculations.
RUD-0162, Rupture Disc, is sized to pass the greatest anticipated discharge, which occurs during a loss of load incident without a reactor trip.
What design features and interlocks provide Primary Coolant System leakage detection?
What design features and interlocks provide Primary Coolant System Overpressure protection?
Power Operated Relief Valves (PORVs) PRV‑1042B, PRV-1043B via LTOP
Over-pressure protection during periods of low temperature or water solid system operation via LTOP or SDC mode.
LTOP – PORV setpoint and alarm setpoints are variable based on system pressure and cold leg temperature
Aligned for automatic system pressure relief prior to 430°F
SDC Mode Pretrip – 265 psia.Trip – 310 psia
Given plant conditions, predict downstream temperature from a lifting or leaking PORV without error.
Use Mollier Diagram. Go straight across (constant enthalpy process)
Describe normal operating values for Quench Tank:
Pressure: 3 psig (N2 cover gas)
Temperature: 104°F
Level: 75%
What are the PCS control room indications for temperature?
Hot Leg RTDs:
Cold Leg RTDS:
.
What are the PCS control room indications for Steam Generator pressure?
Eight (8) DP transmitters in each loop measure pressure drop across S/Gs.
Four (4) DP transmitters connected between the 4 hot leg taps and the 2 suction leg taps, resulting in 4 S/G DPs from hot leg to each suction leg.
What protects the Steam Generator from over pressure conditions?
24 Safety Valves protect the shell side
12 per steam header
Three Groups of four valves
What are the Sub-Cooled Margin Monitors?
Part of Post-Accident Monitoring
Psat and Tsat are calculated from highest measured temperature value
2 Thots/loop, 1 Tcold/cold leg
Max temperature input is used
EK-1120 “LOW SUBCOOLING MARGIN” at less than 25 F
Y-30 – SMM-0114
Y-40 – SMM-0124
What are the Tave Tref controllers?
Inputs
NR safety grade Thot & Tcold (515°F-615°F)
Turbine 1st stage pressure
Outputs – Tave
Calculates a Tave signal from Tc and Th which is then sent to:
TR-0100 on C-02
Average Temp Display SS (outputs to)
Tave from TYT-0200 is sent to TYT-0100 where the Tave loop1/Tave loop 2 deviation alarm is generated at 5°F.
What indications/controls are on C-33?
What are the C-150 Indications?
PCS Loop 1 WR T-cold
HS-0102C must be in the AHSP position to have the following indications:
What is the AHSP/CR Switch on C-150.